7 - Installing Insulation on the Tank
7.1 - Insulation description
Thermal insulation is part of the thermal store to prevent its heat loss. Insulation for this type of thermal store is
installed only at the place of the thermal store installation for easier handling.
Warning
Insulation installation shall be done in two persons. Do not use any tools for installation. Keep away from open fire.
7.2 - How to install the insulation
1. Fix the tank following installation instructions.
2. Wrap the insulation around the tank carefully. Check that the insulation adheres to its body perfectly. This can
be reached by rubbing and patting the insulation by hand from its centre evenly in both directions until the
insulation adheres to the tank’s surface completely and no bubbles are left.
3. Use the holes for connections as a rest during the insulation installation.
4. At least one person presses the insulation to the tank, pulling both ends together. The other person closes
the insulation lock.
5. Put on the upper insulation and cover.
6. Push on the covering plastic rosettes depending on the size of connections.
7. Finish the tank installation in compliance with the respective instructions and valid standards and rules
7.3 - Warranty on insulation
□ Warranty shall become null and void if:
○
the procedure described in the Installation Manual was not respected,
○
the product was used for other purposes than intended.
□ Warranty does not cover:
○
usual wear and tear,
○
damage caused by fire, water, electricity or a natural disaster,
○
defects caused by failure to use the product in compliance with its intended purpose, by improper use
and insufficient maintenance,
○
defects caused by mechanical damage to the product,
○
defects caused by tampering or incompetent repair.