background image

REGULUS - DUO N P Thermal Stores - www.regulus.eu

1 - Description

DUO N P Thermal Stores are intended for storing and subsequent distribution of thermal energy from various 

heat sources like solid-fuel boilers, heat pumps, electric boilers etc. A DHW tank is integrated inside the thermal 

store. For a better thermal layering, the tank volume is separated by a metal plate. The thermal store shall to be 

connected to a closed heating system with forced circulation. 

For proper operation of a tank, it is necessary to have an optimum hydraulic design of the entire heating system, 

i.e. position of circulation pumps for both heat sources and heating circuits, valves, check valves etc. When 

more heat sources shall be combined, it is recommended to use a smart controller for both the heat source and 

heat consumer sections of a heating circuit, i.e. also for charging and discharging a thermal store.

1.1 - Models

Models DUO 390/130 N P, DUO 600/200 N P, DUO 750/200 N P, DUO 1000/200 N P, DUO 1700/200 N P 

permitting installation of electric heating elements and other external heat sources. 

1.2 - Tank protection

The inner DHW tank is made of stainless steel. A chain-type magnesium anode is installed in it for an increased 

level of protection. The thermal store has no inner surface finish, the outer surface is lacquered. 

1.3 - Thermal insulation

Thermal insulation is available as a separate item. For easier handling, the insulation shall not be fitted on the 

tank until it reaches its definite place of installation. The insulation is made of fleece, 100 mm thick, with a hard 

polystyrene surface. It is closed by quick locks.

1.4 - Packaging

Thermal stores are delivered standing, each screwed to its pallet, packed in bubble wrap. The tank is then 

shrink-wrapped together with its pallet.  

It is forbidden to transport and/or store the thermal stores in a horizontal position.

2 - General Information

This Manual is an integral and important part of the product and must be handed over to the User. Read carefully 

the instructions in this Manual as they contain important information concerning safety, installation, operation 

and maintenance. Keep this Manual for later reference. The appliance shall be installed by a qualified person 

according to valid rules and Manufacturer‘s instructions. 

This appliance is designed to accumulate thermal energy of heating water and distribute it subsequently. It 

must be connected to a heating system and heat sources. This appliance is suitable also for storage hot water 

heating. 

Using the thermal store for other purposes than above described is forbidden and the manufacturer accepts no 

responsibility for damage caused by improper or wrong use or filling procedure.

Prior to filling the thermal store, fill and pressurize the inner DHW tank first!!!

Summary of Contents for 19137

Page 1: ...www regulus eu DUO N P DUO N P EN Installation and Operation Manual THERMAL STORES with immersed DHW tank DUO 390 130 N P DUO 600 200 N P DUO 750 200 N P DUO 1000 200 N P DUO 1700 200 N P ...

Page 2: ...gulus DUO N P series 4 4 Operation 6 5 Typical Installation Examples 7 6 Tank Installation and Commissioning 9 6 1 Connection to heat sources 9 6 2 Heating element installation 9 6 3 Connection to water mains 9 6 4 Commissioning 9 7 Installing Insulation on the Tank 10 7 1 Insulation description 10 7 2 How to install the insulation 10 7 3 Warranty on insulation 10 8 Maintenance 11 9 Disposal 11 10...

Page 3: ...ter surface is lacquered 1 3 Thermal insulation Thermal insulation is available as a separate item For easier handling the insulation shall not be fitted on the tank until it reaches its definite place of installation The insulation is made of fleece 100 mm thick with a hard polystyrene surface It is closed by quick locks 1 4 Packaging Thermal stores are delivered standing each screwed to its pall...

Page 4: ...ld water G 1 M4 1910 W2 Hot water G 1 M4 1910 W3 Circulation G 1 M4 1910 N Anode G 1 F 1810 Control and safety C1 Temperature sensor space heating G 1 2 F 1750 C2 Temperature sensor DHW heating G 1 2 F 1510 C3 Temperature sensor DHW heating G 1 2 F 1160 C4 Temperature sensor DHW heating G 1 2 F 1020 T2 Thermometer G 1 2 F 1630 M2 Manometer G 1 2 F 1510 P2 Safety valve G 1 2 F 1400 Air release O2 A...

Page 5: ...10 510 510 510 P G 1 2 F 400 400 400 400 Air release O G 1 2 F 1915 1960 2060 2060 DUO 600 200 N P DUO 750 200 N P DUO 1000 200 N P DUO 1700 200 N P Code tank 19147 19141 19143 19137 Code insulation 19330 19333 19334 19354 Standing loss 102 W 118 W 130 W 175 W Total tank volume 559 l 757 l 903 l 1682 l Fluid volume in tank 385 l 583 l 729 l 1508 l Volume of immersed DHW tank 174 l 174 l 174 l 174 ...

Page 6: ...ttings to both cold and hot water piping possibly also to a hot water recirculation circuit When hot water is drawn from an outlet point cold water flows into the immersed DHW tank and heats up from the heating water in the thermal store to a temperature set by the thermostat placed in the sheath of the DHW tank or in a heating system controller Hot water temperature should be set to 60 65 C This ...

Page 7: ...X 7 pump station for heating system 1 CSE2 8 pump station for DHW recirculation CSE TVMIX ZV 9 safety kit for HW storage tank 10 DHW expansion vessel 11 RegulusBOX indoor unit SV cold water TV hot water CV hot water recirculation ÚT central heating heating system KK ball valve ZV check valve AOV automatic air vent valve PTR pressure temperature relief valve REDV pressure reducing valve optional VK...

Page 8: ...n for heating system 1 CSE2 9 collector manifold HV 60 125 2 10 pump station for DHW recirculation CSE TVMIX ZV 11 safety kit for HW storage tank 12 DHW expansion vessel 13 el heating element for DHW 14 zone valves for DHW heating from HP SV cold water TV hot water CV hot water recirculation ÚT central heating heating system KK ball valve ZV check valve AOV automatic air vent valve PTR pressure te...

Page 9: ...recommend installing an expansion vessel at the cold water inlet with a minimum volume of 4 of the total volume of water in the DHW piping including heat exchangers circulation pipes etc usually 8 l Installation of an expansion vessel is one of the necessary conditions of the extended warranty Should the water be too hard install a water softener upstream of the tank In case the water contains mec...

Page 10: ...mpletely and no bubbles are left 3 Use the holes for connections as a rest during the insulation installation 4 At least one person presses the insulation to the tank pulling both ends together The other person closes the insulation lock 5 Put on the upper insulation and cover 6 Push on the covering plastic rosettes depending on the size of connections 7 Finish the tank installation in compliance ...

Page 11: ...new one Disregarded of its state the magnesium anode rod shall be always replaced with a new one within 24 months from commissioning When replacing the magnesium anode rod first reduce the pressure in the thermal store to atmospheric pressure then reduce the pressure in the DHW tank Replace the anode rod and pressurize the DHW tank then pressurize the thermal store If the tank gets damaged due to ...

Page 12: ... 2022 We reserve the right to errors changes and improvements without prior notice REGULUS spol s r o E mail sales regulus eu Web www regulus eu v1 0 04 2022 ...