8
REGULUS - DUO N P Thermal Stores - www.regulus.eu
Variant 2:
Heat pump with hydronic fireplace insert and el. heating elements
KEY
1 – Regulus heat pump (R
TC, CTC)
2 – heating system expansion vessel 3 – el. heating elements for space heating
4 – Regulus DUO xx N P
thermal store
5 – RGMA
T E load unit
6 – fireplace insert (stove) w
. hydronic heat exchanger
7 – pump station for heating system 2 - CSE2 MIX 8 – pump station for heating system 1 - CSE2 9 – collector/manifold, HV 60/125-2 10 – pump station for DHW recirculation – CSE
TVMIX ZV
11 – safety kit for HW storage tank 12 – DHW expansion vessel 13 – el. heating element for DHW 14 – zone valves for DHW heating from HP
SV – cold water TV – hot water CV – hot water recirculation ÚT
– central heating (heating system)
KK
– ball valve
ZV
– check valve
AOV
– automatic air vent valve
PTR
– pressure temperature relief valve
REDV
– pressure reducing valve (optional)
VK
– drain valve
SVE
– expansion vessel service valve
PV
-ÚT
– safety valve for heating system
MFB
– Magnet Filterball
BRAIDED HOSE
COMPENSA
TOR