Collector description

REGULUS

 Flat Solar Collectors are designed for solar 

domestic hot water heating (DHW), backup- and pool 
heating with solar energy. Solar radiation penetrates the 
glass and is intercepted by an ef

fi

 cient absorption layer 

applied on an all aluminum absorber. The heat is then 
transferred into heat transfer 

fl

 uid. The absorber is sea-

led in a compact frame with high quality thermal insulati-
on. The collectors are designed for year round operation, 
that’s why they work in a separate primary circuit 

fi

 lled 

with antifreeze heat carrier.

 The collectors are 

not intended

 for direct wa-

ter heating. If different heat transfer 

fl

 uid is used 

than speci

fi

 ed by the manufacturer, irreversible 

damage to the collector may be done.

Transport, handling and storing

Collectors shall be transported in their original packing, 
in upright position (standing on their shorter side) or lying 
horizontal with glass upwards, stack of max. 14 pieces 
on a pallet.
During handling the collector glass shall be always 
facing upwards.
Please check the condition of the collector upon recepti-
on from your supplier or forwarder. Later claimed mecha-
nical damage (frame, glass, connection) will be refused.
When stored, the collector shall not be exposed to rain 
and its absorber exposed to solar radiation.  

Scope of supply

1. KPG1-ALC collector
2. Instruction manual
3. Warrant Certi

fi

 cate

General instructions for installation

The installation must be done by a trained worker or a 
specialized company. 
During installation and before commissioning, it is 
necessary to cover collectors in order to avoid overhea-
ting and possible burn injury to the installer. 
Prior to installation, conditions set by the roo

fi

 ng manu-

facturer and the max. permissible roof load shall be 
checked.  
Mounting method for solar collectors shall always re-
spect local conditions, i.e. roof inclination and weather 
in

fl

 uence on the overall load on the collector. Kindly con-

sult the fastening method with a structural statics expert.  

During installation the collectors and accessories shall 
be handled carefully. Defects caused by improper hand-
ling or DIY installation are not cover by warranty. 
Generally valid rules and standards for occupational 
safety shall be respected during installation. This con-
cerns mainly technicians walking on a roof and the secu-
ring the area against objects falling down from a roof.
Only REGULUS mount elements may be used. Other 
fastening elements may be used only with a written 
approval from REGULUS company. 
Collectors shall not be exposed to solar radiation un-
til commissioned. The absorption surface may get 
damaged.
Collectors shall be installed and operated in compliance 
with this Manual and with respective generally valid rules 
and norms.

Collector placing

The collector must be placed outdoors. The glass 
absorption surface should be orientated to South, with 
deviations not over 45° (Southwest or Southeast). For a 
year round operation the right inclination angle is 40°-
50°, for summer operation smaller inclination is better 
(30°).
Collectors are installed according to marking.

The collectors shall be installed at an angle 
between 15° and 75°.

On inclined roofs it is recommended to install 

solar collectors as close to the roof ridge as possible. 
Should this solution be impossible, then protections 
against snow slide shall be installed above the collec-
tors. 
The numbers of roof anchors shown in the Mount Kits 
for Fitting and Connecting Regulus Solar Collectors are 
designed for the following load:
Max. permissible snow and wind load 

 

1,8 kN/m

2

Max. permissible wind load - negative pressure 

 

1,0 kN/m

2

The customer/user shall be informed about this fact prior 
to starting installation of a solar system. If a higher load 
than shown above is expected in the area in question, a 
statics expert shall be consulted and more roof anchors 
designed, or other measures taken that would ensure 
safe collector 

fi

 tting.  Regulus refuses any responsibility 

for damage  caused by wrong design of collector faste-
ning.

 

GENERAL INSTALLATION AND OPERATION INSTRUCTIONS

Summary of Contents for KPG1-ALC

Page 1: ...1 1 Solar System with KPG1 ALC Collectors EN v 1 4 Installation and Operation Manual...

Page 2: ...interconnecting 16 6 Temperature Probe Positioning 18 7 Pump Station 19 8 Expansion Vessel Sizing and Working Pressure Calculation 20 8 1 Expansion vessel sizing 20 8 2 Calculation of a system workin...

Page 3: ...ly con sult the fastening method with a structural statics expert During installation the collectors and accessories shall be handled carefully Defects caused by improper hand ling or DIY installation...

Page 4: ...owing chart by the roof type and roofing material Supports and struts for flat roof installation Code Triangle support strut 15 11979 Triangle support strut 25 10975 Triangle support strut 45 6859 Str...

Page 5: ...m 6949 4 M8 nut for the rails 4 pcs 6 pcs 8 pcs 10 pcs 6925 5 M8 16 bolt with allen head 4 pcs 4 pcs 4 pcs 4 pcs 6926 6 Retaining side bracket 4 pcs 4 pcs 4 pcs 4 pcs 10522 10 Retaining bracket betwe...

Page 6: ...pcs 13695 22 mm nipple blind 2 pcs 2 pcs 13696 Nipple 3 4 M M thick wall 4 pcs 2 pcs 6970 3 4 FF elbow brass 1 pcs 1 pcs 10192 T piece in brass 3 4 FFF 1 pcs 7180 X piece in brass 4x 3 4 F 1 pcs 7184...

Page 7: ...boards can be inserted approx distance between boards 1600 1800 mm For roof tiles just shifting them upwards in the length of the auxiliary board is sufficient see Fig 4 Fit the auxiliary boards to ba...

Page 8: ...r Simply lay the anchor onto the roof tiles and fasten it with stainless steel bolts If the roofing is made of e g copper or zinc pla ted iron then the anchor contact surface shall be isolated using s...

Page 9: ...45 150 7 5 e Roofing bolt for rail fastening RIGHT 10 30 mm Fig 8 Right anchor position with roof tiles c Roof anchor of stainless steel or zinc plated steel for pantiles a Stainless steel anchor on...

Page 10: ...the bottom rail 2 brackets per collector Insert the retaining brackets into the bottom rail about 100 mm from the collector edge Lay the first collector carefully on the rails and align it in the bra...

Page 11: ...en the nuts More on this in chapter 5 Hydraulic Connection Continue mounting further collectors in the same way see page 14 48 6 7 5 For passing the connection pipes through a roof e g ventilation til...

Page 12: ...cs 10 pcs 12 pcs 6925 6 M8x16 stainless steel bolt allen head 4 pcs 4 pcs 4 pcs 4 pcs 4 pcs 6926 7 Retaining side bracket 4 pcs 4 pcs 4 pcs 4 pcs 4 pcs 10522 11 Retaining bracket between 2 collectors...

Page 13: ...bow 1 pcs 1 pcs 10192 T piece in brass 3 4 FFF 1 pcs 7180 X piece in brass 4x 3 4 F 1 pcs 7184 3 4 plug gasket brass for code 7628 1 pcs 7954 1 2 3 4 F M brass hex nipple 1 pcs 6964 Single sheath 7x8...

Page 14: ...es cca 350 mm D2 2 4 4 1660 mm T strut base rails L strut D1 Fig 15 Aligning the rails and mounting the first triangular support Assemble the triangular supports that come partially screwed together F...

Page 15: ...ular supports is similar to that of roof anchors in Fig 2 and the last support shall be located about 350 mm from the ends of both rails After fitting the strut and other supports kip the entire struc...

Page 16: ...e first one maintaining a sufficient gap Then put the threaded fittings on both the upper and lower outlets and push the collector to the already mounted one until stop Hold the fitting with a spanner...

Page 17: ...kit for landscape installation code 14134 All solar components must be carefully and safely sealed and must be made of material resistant to glycol and temperatures up to 160 C For connection piping...

Page 18: ...TIONING Tab 1 Recommended pipe diameters AV23 Flow rate regulator with indicator 2 12 l min 3 4 3 8 air discharge valve and 3 8 ball valve up to 160 C Fig 24 Variants of non typical connections Place...

Page 19: ...0 C No shut off valve shall be installed between a safety valve and collectors Fig 26 Solar Pump Station 1 2 3 4 5 6 7 8 9 10 1 Ball valve on flow line red frame thermometer 0 120 C dial with check va...

Page 20: ...ssure in a solar system bar h height from a pressure gauge to the middle of a col lector field m Adjust the pressure by discharging solar liquid after the pressure test is done 8 3 Calculation of expa...

Page 21: ...from the fluid see pic 29 A ball valve shall be always installed under the automatic air vent valve so that the automatic air vent can be clo sed after the system commissioning Solar liquid leaks can...

Page 22: ...ct the filling pump hoses set the circulation pump s to the highest speed and repeat switching on and off to air bleed the system an air free pump works almost noiselessly watch the system pressure an...

Page 23: ...hecked Once a year preferably during a sunny day it is necessary to check the working order and tight fastening of the collectors verify the system tightness and pressure incl pressure in the expansio...

Page 24: ...22 mm 0 8 mm absorber tube material copper absorber tube dimension 12 8 mm 0 5 mm solar absorptance 94 2 emmisivity 5 2 max working pressure 10 bar max working temperature 120 C stagnation temperature...

Page 25: ...v ztr ta kolektoru KPG1 ALC Collector power output in zero point for G 1000 W m2 is 1839 W Momentary collector efficiency over the aperture area for 1000 W m2 insolation Temperature difference between...

Page 26: ...26 84 70 6 1 1 2151 2010 70 1212 1170 21 21 22 15 CONNECTION DIMENSIONS...

Page 27: ...eck pipe insulation Check the proper flow rate Check temperature probes Check the quality of antifreeze liquid with a refractometer Check the heat carrier pressure replenish if necessary Check the con...

Page 28: ...28...

Page 29: ...the service action This Service Action has been carried out by an authorized servicing company Date of Service Action Name of the servicing company Address of the servicing company Name of the servic...

Page 30: ...30...

Page 31: ...31...

Page 32: ...32 02 2015 REGULUS spol s r o Do Kout 1897 3 143 00 Praha 4 http www regulus eu E mail sales regulus cz Your service...