background image

4

Mounting kits for fi tting and connecting KPG1-ALC solar collectors

Code

Connection kit for a KPC1, KPS11, KPG1,KPH1, KTU collector array
(3/4“ M inlet and 3/4“ M outlet with a pocket for solar temperature sensor)

7710

Connection kit for KPG1 collector array, landscape installation

14134

Mount kit for one KPG 1 collector *[for 4 anchors or 2 s1 strut]

10538

Mount and interconnection kit for 2 KPG 1 collectors *[for 6 anchors or 3 s1 strut]

10539

Mount and interconnection kit for 3 KPG 1 collectors *[for 8 anchors or 4 s1 strut]

10540

Mount and interconnection kit for 4 KPG 1 collectors *[for 10 anchors or 5 s1 strut] 10541

Mount and interconnection kit for 5 KPG 1 collectors *[for 12 anchors or 6 s1 strut] 14067

* Roof mount and interconnecting kits are necessary to create a hydraulically connected collector array 

fi tted to 2 mounting rails. The kits contain interconnecting fi ttings with insulation, two mounting rails, 
fastening material for mounting collectors onto the rails. They do not involve any roof anchors, supports, 
struts. These shall be selected from the following  chart by the roof type and roofi ng material.

Supports and struts for fl at roof installation

Code

Triangle support strut 15°

11979

Triangle support strut 25°

10975

Triangle support strut 45°

6859

Strut incl. screws for triangle support

9563

Supports for sloping roof installation

Code

Triangle strut 15°

10748

Triangle strut 25°

8805

Triangle strut 45°

10094

Triangle strut 60°

9631

Anchors for various roofi ng types

Code

Stainless-steel anchor for slate roofs

11574

Anchor for pantiles - hot-dip galvanized steel

7929

Aluminum anchor for pantiles - rafter mounted

6932

Stainless-steel anchor for pantiles

6857

Stainless steel anchor for pantiles - rafter mounted, incl. self tapping screws

10159

Bolt for 

fi

 tting rails onto a roof

7320

 1. DELIVERY OF MOUNTING SYSTEM

Supports and support strut for horizontal installation on fl at roof

Code

Triangle support strut 25°

10907

Triangle support strut 45°

10921

Support strut incl. bolts for triangle supports, for horizontal installation on 

fl

 at roof 

10908

Supports for horizontal installation on sloping roof 

Kód

Triangle strut 15° for horizontal installation on sloping roof

11070

Triangle strut 25° for horizontal installation on sloping roof

11071

Triangle strut 45° for horizontal installation on sloping roof

11072

Wall Bracket for KPG1, landscape, pitch 45°

12786

Summary of Contents for KPG1-ALC

Page 1: ...1 1 Solar System with KPG1 ALC Collectors EN v 1 4 Installation and Operation Manual...

Page 2: ...interconnecting 16 6 Temperature Probe Positioning 18 7 Pump Station 19 8 Expansion Vessel Sizing and Working Pressure Calculation 20 8 1 Expansion vessel sizing 20 8 2 Calculation of a system workin...

Page 3: ...ly con sult the fastening method with a structural statics expert During installation the collectors and accessories shall be handled carefully Defects caused by improper hand ling or DIY installation...

Page 4: ...owing chart by the roof type and roofing material Supports and struts for flat roof installation Code Triangle support strut 15 11979 Triangle support strut 25 10975 Triangle support strut 45 6859 Str...

Page 5: ...m 6949 4 M8 nut for the rails 4 pcs 6 pcs 8 pcs 10 pcs 6925 5 M8 16 bolt with allen head 4 pcs 4 pcs 4 pcs 4 pcs 6926 6 Retaining side bracket 4 pcs 4 pcs 4 pcs 4 pcs 10522 10 Retaining bracket betwe...

Page 6: ...pcs 13695 22 mm nipple blind 2 pcs 2 pcs 13696 Nipple 3 4 M M thick wall 4 pcs 2 pcs 6970 3 4 FF elbow brass 1 pcs 1 pcs 10192 T piece in brass 3 4 FFF 1 pcs 7180 X piece in brass 4x 3 4 F 1 pcs 7184...

Page 7: ...boards can be inserted approx distance between boards 1600 1800 mm For roof tiles just shifting them upwards in the length of the auxiliary board is sufficient see Fig 4 Fit the auxiliary boards to ba...

Page 8: ...r Simply lay the anchor onto the roof tiles and fasten it with stainless steel bolts If the roofing is made of e g copper or zinc pla ted iron then the anchor contact surface shall be isolated using s...

Page 9: ...45 150 7 5 e Roofing bolt for rail fastening RIGHT 10 30 mm Fig 8 Right anchor position with roof tiles c Roof anchor of stainless steel or zinc plated steel for pantiles a Stainless steel anchor on...

Page 10: ...the bottom rail 2 brackets per collector Insert the retaining brackets into the bottom rail about 100 mm from the collector edge Lay the first collector carefully on the rails and align it in the bra...

Page 11: ...en the nuts More on this in chapter 5 Hydraulic Connection Continue mounting further collectors in the same way see page 14 48 6 7 5 For passing the connection pipes through a roof e g ventilation til...

Page 12: ...cs 10 pcs 12 pcs 6925 6 M8x16 stainless steel bolt allen head 4 pcs 4 pcs 4 pcs 4 pcs 4 pcs 6926 7 Retaining side bracket 4 pcs 4 pcs 4 pcs 4 pcs 4 pcs 10522 11 Retaining bracket between 2 collectors...

Page 13: ...bow 1 pcs 1 pcs 10192 T piece in brass 3 4 FFF 1 pcs 7180 X piece in brass 4x 3 4 F 1 pcs 7184 3 4 plug gasket brass for code 7628 1 pcs 7954 1 2 3 4 F M brass hex nipple 1 pcs 6964 Single sheath 7x8...

Page 14: ...es cca 350 mm D2 2 4 4 1660 mm T strut base rails L strut D1 Fig 15 Aligning the rails and mounting the first triangular support Assemble the triangular supports that come partially screwed together F...

Page 15: ...ular supports is similar to that of roof anchors in Fig 2 and the last support shall be located about 350 mm from the ends of both rails After fitting the strut and other supports kip the entire struc...

Page 16: ...e first one maintaining a sufficient gap Then put the threaded fittings on both the upper and lower outlets and push the collector to the already mounted one until stop Hold the fitting with a spanner...

Page 17: ...kit for landscape installation code 14134 All solar components must be carefully and safely sealed and must be made of material resistant to glycol and temperatures up to 160 C For connection piping...

Page 18: ...TIONING Tab 1 Recommended pipe diameters AV23 Flow rate regulator with indicator 2 12 l min 3 4 3 8 air discharge valve and 3 8 ball valve up to 160 C Fig 24 Variants of non typical connections Place...

Page 19: ...0 C No shut off valve shall be installed between a safety valve and collectors Fig 26 Solar Pump Station 1 2 3 4 5 6 7 8 9 10 1 Ball valve on flow line red frame thermometer 0 120 C dial with check va...

Page 20: ...ssure in a solar system bar h height from a pressure gauge to the middle of a col lector field m Adjust the pressure by discharging solar liquid after the pressure test is done 8 3 Calculation of expa...

Page 21: ...from the fluid see pic 29 A ball valve shall be always installed under the automatic air vent valve so that the automatic air vent can be clo sed after the system commissioning Solar liquid leaks can...

Page 22: ...ct the filling pump hoses set the circulation pump s to the highest speed and repeat switching on and off to air bleed the system an air free pump works almost noiselessly watch the system pressure an...

Page 23: ...hecked Once a year preferably during a sunny day it is necessary to check the working order and tight fastening of the collectors verify the system tightness and pressure incl pressure in the expansio...

Page 24: ...22 mm 0 8 mm absorber tube material copper absorber tube dimension 12 8 mm 0 5 mm solar absorptance 94 2 emmisivity 5 2 max working pressure 10 bar max working temperature 120 C stagnation temperature...

Page 25: ...v ztr ta kolektoru KPG1 ALC Collector power output in zero point for G 1000 W m2 is 1839 W Momentary collector efficiency over the aperture area for 1000 W m2 insolation Temperature difference between...

Page 26: ...26 84 70 6 1 1 2151 2010 70 1212 1170 21 21 22 15 CONNECTION DIMENSIONS...

Page 27: ...eck pipe insulation Check the proper flow rate Check temperature probes Check the quality of antifreeze liquid with a refractometer Check the heat carrier pressure replenish if necessary Check the con...

Page 28: ...28...

Page 29: ...the service action This Service Action has been carried out by an authorized servicing company Date of Service Action Name of the servicing company Address of the servicing company Name of the servic...

Page 30: ...30...

Page 31: ...31...

Page 32: ...32 02 2015 REGULUS spol s r o Do Kout 1897 3 143 00 Praha 4 http www regulus eu E mail sales regulus cz Your service...