14. Fit the solar pump station (code 14866) using 2 screws M6x16 and washers (codes
      12996 and 7853) - all these components are included in the Kit code 12227.

15. Connect the solar pump station to the tank using the respective Kit (code 12227). Prior 
      to 

fi

tting, cut the insulation to length and slide it onto the pipe. Fit the solar sheath.

   

 

 

 

 

 

 

          

SHEATH

16. Stretch the pipes to the below listed preliminary lengths, cut the insulation and slide
      it onto the pipes (included in the Kit code 12226):
   

 one 1” pipe (code 11271) to 410 mm, insulation to some 500 mm

   

 one 1” pipe (code 3016) to 250 mm, insulation to some 300 mm

   

 one 3/4” pipe (code 3041) to 450 mm, insulation to some 550mm

   

 one 3/4” pipe (code 3041) to 320 mm, insulation to some 400 mm

   

 one 5/4” DN25 pipe (code 13484) to 580 mm, insulation to some 700 mm

 

  

 

 

Summary of Contents for LYRA 1000 VVS

Page 1: ...www regulus eu LYRA 1000 VVS LYRA 1000 VVS EN Installation and Operation Manual LYRA 1000VVSTHERMAL STORE...

Page 2: ...ons 4 4 Operation 4 5 Connections 5 5 1 Mounting pump stations and accessories onto LYRA 5 5 2 Connecting heating circuits 17 5 3 Connecting DHW circuit 17 5 4 Connecting solar circuit 17 5 5 Examples...

Page 3: ...in gray 1 3 Thermal insulation Thermal insulation is included in the scope of delivery The insulation consists of 3 layers the first layer is made of soft insulation tightly fitting to the tank The s...

Page 4: ...heat sources like various types of hot water boilers renewable energy sources heat pumps solar collectors or electric heating elements code Total fluid volume Fluid volume in tank Fluid volume in hea...

Page 5: ...ion for cover for pump station with 2 circuits 1 pcs 12713 Black knurled screw M6x1 10 PA 6 6 4 pcs 13437 Kit for connecting expansion vessel to LYRA 1 pcs 12226 Assy Connection Kit for LYRA Code Name...

Page 6: ...ulation DNa 28 13 mm thick 2 m 0 5 m 10845 Capillary spring small 1 2 stainless steel 1 m 9980 1 PTFE Nut Gasket 18 5x30x2 mm 2 pcs 12996 M 6x16 Stainless Steel Bolt Allen head DIN 912 A2 2 pcs 7853 W...

Page 7: ...ncluded in separate kits 1 Remove the tank from its pallet and place it to its approximate position shift the bottom insulation under the tank 2 Slide the insulation inserts into the openings for conn...

Page 8: ...ll be used in places where openings are close to each other the annuluses overlap 5 Fit the assembly with elbow ball valve code 12690 From this point on it is important to stick to the sequence of ins...

Page 9: ...6 into the lower 1 opening 10 Align the metal sheet against the four pins and fix it using 4 screws M6x16 with washers codes 12996 and 7853 both these components are included in the Kit code 12226 Do...

Page 10: ...6 with washers codes 12996 and 7853 all these components are included in the Kit code 12226 12 Connect the TSV3B assembly code 12687 using a 3 4 pipe 100 mm long code 11946 included in Kit 13234 with...

Page 11: ...slide it onto the pipe Fit the solar sheath SHEATH 16 Stretch the pipes to the below listed preliminary lengths cut the insulation and slide it onto the pipes included in the Kit code 12226 one 1 pipe...

Page 12: ...1 elbow of the pump station with 4 way valves 18 Fit the 1 pipe 410 mm long code 11271 connect the zone valve assy with onto the pump station 19 Fit the 3 4 pipes 320 and 450 mm long code 3041 to the...

Page 13: ...ipe 580 mm long connect the T piece assy with the ball valve assy 22 Fit two thermometers code 10474 included in Kit 13237 and 6 4 and 1 2 plugs or electric heating elements and a safety thermostat TH...

Page 14: ...into the sleeve and then the safety valve code 605 included in Kit 13237 24 Push the front insulation onto the pump station with 4 way valves 25 Connect the terminals of the pumps with cables push th...

Page 15: ...way valves and fix it with 4 plastic screws M6x10 code 12713 27 Fit the top insulation and the top plastic cover onto the tank 28 Fit the automatic air release valve code 11708 with ball valve code 1...

Page 16: ...16 Completely fitted tank ed tank...

Page 17: ...As a variant LYRA can be supplied with a pump station for one heating circuit only 1 Hot water outlet G3 4 M 2 Hot water recirculation G3 4 M 3 Cold water inlet G3 4 M As a variant LYRA can be supplie...

Page 18: ...for heating EXAMPLE I Hydronic fireplace insert with heat exchanger and hydronic boiler electric gas oil or wood pellet fired safety temp limiter el heating elements heat pump max flow temp 55 C hydro...

Page 19: ...pper tank section left from the pump station for heating circuits The G1 2 port above the el heating element ports is intended for a safety temperature limiter All el heating elements shall be install...

Page 20: ...fluids and air bleed the entire system Check all connections for leaks and verify the system pressure Set the heating controller in compliance with the documentation and manufacturer s recommendations...

Reviews: