3 PROTECTION SYSTEM
15
ALPIN100 Manual © Copyright 2010 by Reimesch Kommunikationssysteme GmbH
3.
PROTECTION SYSTEM
This amplifier uses a very complex protection system. If an error occurs, the amplifier
switches to standby or off mode and prints an error code to the display.
In this way, the protection system is able to avoid a series of potential damages to the
amplifier, but there is no reason to operate carelessly.
3.1.
Errors in
Power On
mode:
Code
Legend
17
average plate voltage too high
18
IG2 too high
19
plate current too high
20
grid RF too high
21
problem with output relay contact
22
screen current too high
23
HV < 350V for more than 120 ms
24
HV > 3300V or HV < 1500V
25
low air for > 90 s
3.2.
Errors in
Standby
mode:
Code
Legend
33
plate current > 25mA
34
high voltage > 3300V or high voltage < 1500V
35
temperature > 115°C
36
problem with output relay contact
37
G1 screen current
38
low air for > 90 s
39
problem in low voltage supply
40
drive power > 0.44W
41
average plate voltage > 480V
42
G2 screen current > 5mA