3 PROTECTION SYSTEM
16
ALPIN100 Manual © Copyright 2010 by Reimesch Kommunikationssysteme GmbH
3.3.
Errors in
Operate
mode:
Code
Legend
49
plate current > 1.2 A
50
problem in low voltage supply
51
low air for > 90 s
52
HV > 3300V or HV < 1500V
3.4.
Errors in
TX/RX
mode:
Code
Legend
64
problem with output relay contact
66
output relay contact switch 5ms problem
67
output relay contact switch 5ms problem
68
Grid RF and PANT are not ok
3.5.
Warnings in
Operate
mode:
Besides those errors there are some warnings in the
Operate
mode. The amplifier shows a
flashing warning message and/or will switch to
Standby
mode.
Message
Legend
Action
REFLECTED PWR
Reflected power > 350W
Standby
mode
DRIVE TOO HIGH
Drive power > 90W for less than 5 s
Drive power > 90W for more than 5s
Drive power > 120W
Warning
Standby
mode
Standby
mode
SCREEN CURRENT
Screen current > 80mA for more than 1s
Standby
mode
PLATE CURRENT
Plate current > 700mA
Plate current > 800mA for more than 2s
Warning
Standby
mode
OVERHEATING
Temperature > 97°C ( 207° F)
Temperature > 115°C ( 239° F)
Warning
Standby
mode
ARC FAULT
Recognized arc
Standby
mode
GRID CURRENT
Grid current too high
Standby
mode