1 INSTALLATION AND SETUP
6
ALPIN100 Manual © Copyright 2010 by Reimesch Kommunikationssysteme GmbH
SETUP
1)
Connect the RF-Input connector from the ALPIN 100 to the Transceiver Antenna Port
(TRX IN/Out).
2)
Connect a suitable antenna or artificial load being able to handle the output power
delivered by the ALPIN 100.
3)
Connect the PTT – Line from your transceiver to the RELAY jack of the ALPIN 100.
The voltage on the Relay Jack is 12V and the current to ground is 11mA.
4)
For QSK Operation connect your KEYER to the “RELAY” Jack and connect the KEY
OUT jack on the rear of the ALPIN 100 to the KEY INPUT of your transceiver.
5)
Connect the amplifier to the AC – Mains (230VAC) and switch on the MAINS
POWER SWITCH on the rear of the ALPIN 100.