1 INSTALLATION AND SETUP
8
ALPIN100 Manual © Copyright 2010 by Reimesch Kommunikationssysteme GmbH
TOP SIDE CONNECTIONS
The default configuration of the top side connections of the transformer is configured for
230V shown in the table below. The 2 cables from the fuse board are always connected to
1
and
4
.
If the voltage of the power system is different from the default configuration you will have to
change the position of the connector cables as shown in the table. The cables are marked from
A to H and the connection points from 1 to 8. :
Line
1
2
3
4
5
6
7
8
Fuse
120V
H&G C
D
A
B
E
F
20A
200V
E
D
B&H A
C
F
G
12A
210V
F
D
B&H A
C
E
G
12A
220V
G
D
B&H A
C
E
F
12A
230V
F
D
C&H A
B
E
G
10A
240V
G
D
C&H A
B
E
F
10A
Besides this, you have to configure two jumpers on the main board next to the transformer.
The pin numbers are printed on the board.
Line
Jumper 1
Jumper 2
120V
Pin 1 & 2
Pin 3 & 4
200-240V
Pin 2 & 3
Pin 4 & 5
8
7
6
5
4
3
2
1
High Voltage board side
Main board