REINHARDT
System- und Messelectronic GmbH
Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196/7001
PM BD MWS6 E Page 11 of 34
erstellt am 02.11.2000
Manual MWS 6
With GRAF_COL.DAT you can set the desktop colours as you like.
The numbers and colours are coordinated as follows:
Foreground and background colours :
0-black, 1-blue, 2-green, 3-cyan, 4-red, 5-magenta, 6-brown, 7-light grey.
Foreground-colours:
8-dark grey, 9-light blue, 10-light green, 11- light cyan, 12-light red, 13-light
magenta, 14-yellow, 15-white
You can set this with MWSSET.EXE.
MWS2_SET.DAT contains the sensor names, units and diverse control parameters.
You can enter the names of the measured value windows and the units for possible
additional sensors. All other parameters should be left unchanged, because inexpert
changes can result in a completely wrong measurement.
Please see MWS2_SET.DOK.
KLI_SCOM.DAT is a control file of the interface.
It contains the configuration values of the COM-ports.
The following values are possible:
Line 1:
Entry of the data source (0..3 means COM1..4)
If you do not want to read in the weather data directly from the interface
but from a file, you just enter the path name where the weather data are
stored and not the interface identification, e.g.: F:\DATEN\WETTER.
If the data must not be written into the MWS6-directory, you enter the
desired data path after the interface identification and separate it by a
comma, e.g. for interface COM2 and data path D:\WETTER :
1,D:\WETTER.
You may need these possibilities if you use your weather station in a
network and want to have access to the weather data from several
computers.
(Please also see the readme-file!)
If you want to use the software for the history function only you enter -1
in this field. This de-activates the interface.
Line 2:
Number of data bits
Line 3:
Number of stop bits
Line 4:
Parity
Line 5:
Baud rate
Line 6:
DOS-ID number (Standard 193), please change if necessary (e.g. in
networks).
Line 7:
Interval for data storage to harddisk (ab V1.10).
You can also set this with MWSSET.EXE.
The storage interval can be set in a 10 seconds raster and lasts from a minimum 30
seconds to a maximum 40 minutes.
GRAF_COL.DAT
MWS2_SET.DAT
KLI_SCOM.DAT
Storage Interval