MWS_55_e.indb Page 123
Manual MWS 55 / MWS 88 / MWS 10 and Sensors 55
geändert am 04.12.2020 von DO
REINHARDT
System- und Messelectronic GmbH
Fax: 08196/7005 and 1414 email:
wetter@reinhardt-testsystem.de
http://www.reinhardt-wetterstationen.de
ADMIN STATION NAME
Name
*ADMIN STATION NAME
Name
sets the station name, which is listed in the SMS as headline over the sensor identifiers and its
values.
Any 19 characters are allowed (numbers, lowercase and uppercase letters, special characters).
Please note that special characters in the GSM character set may not be included.
Pay attention to short names to ensure a good readability of the SMS.
ADMIN STATION BAUD x
*ADMIN STATION BAUD x
Sets the baud rate of the serial port.
Valid bausrates are: 300,600,1200,2400,4800,9600,19200,38400,57600 oder 115200.
All other values will be ignored.
ADMIN GET STATION
*ADMIN GET STATION
Returns the parameters previously set with ADMIN STATION …
STATION
>IDENT 255
>BAUD 9600
>NAME Reinhardt MWS
ADMIN STATION SENSOR x NUMBER
s
*ADMIN STATION SENSOR x NUMBER
s
Define sensor position x (1..32) with sensor s.
ADMIN STATION SENSOR x IDENT
cccc
*ADMIN STATION SENSOR x IDENT
cccc
cccc: Prefix, maximum four characters from the following selection, set in front of the measured
value in the output string:
0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz_#@§$%&/()=~
and the space, which must not be the 1st character (will be skipped).
ASCII-sign 126 (= "~") suppesses the character output.
i.e.
ADMIN STATION SENSOR 2 IDENT TE
ADMIN STATION SENSOR x NAME
Name
*ADMIN STATION SENSOR x NAME
Name
Sets the sensor name (i.e. Temperature).
Any 19 characters from the following selection are allowed:
0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrst-;.#@§$%&/
()=~
and the space, which must not be the 1st character (will be skipped).
Please note that special characters in the GSM character set may not be included.
Pay attention to short names to ensure a good readability of the SMS.
i.e.
ADMIN STATION SENSOR 2 NAME Temperature