Manual MWS 55 / MWS 88 / MWS 10 and Sensors 55
4.4.3 WEB-Server
To use the station as WEB-server, the HTTP protocol needs to be enabled (see !DC or ?DC, Bit 24).
To use the station as WEB server the HTTP protocol must be enabled. (see !DC or ?DC, Bit 24)
Also the Ethernet port must be enabled
(
!F+24
or
*ADMIN SET PERMIT 15 ON
) or being configured.
This already is preconfigured when ordering a station with TCP/IP PoE option!
It is important that at the access permissions with *
ADMIN SET INCLUDE
the connection
type HTTP (or HTTP* for privileged access) is added. Access from an IP / MAC address not being
enabled for this connection type will get no answer!
A HTTP read access may be granted with the command
*ADMIN SET INCLUDE 192.168.0.12
[HTTP]
.
If the station hasn't got an internal SD-card, via the HTTP port 80 an internal default page can
be retrieved from the stations IP-address (set by
*ADMIN ETHERNET IP
).