background image

1 0

Trouble­Shooting

List of possible fault indications and assistance in trouble­shooting

In case of damage, send the glue applicator to Reka, indicating type and serial no. of your applicator. Self­made repairs void the

warranty.

Summary of Contents for TR 50.4 25

Page 1: ...0 4 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR 80 LCD Product Manual for Pneumatic Reka Glue Guns Translation from German to English www pakarte com TR 50 4 25 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR 80...

Page 2: ...rouble Shooting 10 Environmental Protection 11 Additional Information 11 EU Declaration of Conformity 12 Spare Parts Technical Specifications Accessories TR 50 4 14 TR 55 LCD HT 16 TR 60 LCD HT 18 TR...

Page 3: ...Leopoldshafen October 1st 2012 The applicator works with hot glue which is dispensed by a pneumatic conveying system Therefore this glue applicator should only be used by qualified persons who have be...

Page 4: ...Available This operating manual shall always be kept at the place of operation of the applicator Be sure that all persons handling the applicator can consult the instructions at any time In addition t...

Page 5: ...risk of burns When a nozzle is replaced liquid glue might leak out Never bring the hot nozzle into contact with the cable Never direct the glue jet towards people Wear protective gloves and safety go...

Page 6: ...x 1 5 cm below upper rim Stop using the equipment if the casing is damaged due to shock breakage or heavy wear Is compressed air supplied to the glue applicator Is the applicator connected to a compre...

Page 7: ...ancer Suspender If the glue applicator is fixed to a balancer suspender it is recommended to use the suspension 10436 Thereby it is avoided that by a wrong positioning glue gets into the vent valve Th...

Page 8: ...ely in the cartridge Wear protective gloves and safety goggles whenever you work with the applicator When the applicator has warmed up there is a risk of burns If when changing the cartridge another t...

Page 9: ...t glues Please check whether the complete spray head drawing Detail Front is fitted to the applicator if this is not the case attach it The spray cap 3088 must be screwed on slightly by hand never use...

Page 10: ...and can be used for glueing again The working temperature of the respective glue may be taken from the technical datasheet which can be procured from the producer of the glue This temperature must not...

Page 11: ...rom getting into the sound absorber when the applicator is ready for operation by depositing the glue applicator on a level plane using its wire bracket depositing the glue applicator on the stand 277...

Page 12: ...hooting List of possible fault indications and assistance in trouble shooting In case of damage send the glue applicator to Reka indicating type and serial no of your applicator Self made repairs void...

Page 13: ...cking material used by Reka Klebetechnik can be recycled completely Please take instructions for the disposal of hot melt glues and hot melt cartridges from the respective safety specifications Additi...

Page 14: ...C from 20 09 2009 2004 108 EC until 28 12 2009 89 336 EEC from 29 12 2009 2006 42 EC 2002 95 EC The following standards have been applied IEC CISPR14 IEC 60335 IEC 60204 IEC 61000 This declaration of...

Page 15: ...1 3 TR 50 4 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR 80 LCD Spare Parts Technical Specifications Accessories...

Page 16: ...1 4 Spare Parts TR 50 4...

Page 17: ...perating temperature 20 200 C Consistency of temperature 5 C Temperature indication analog Heat up time approx 3 10 min Gross Tank Capacity 250 ml Conveying system Air pressure Operating pressure 0 5...

Page 18: ...1 6 Spare Parts TR 55 LCD HT...

Page 19: ...Temperature limitation Temperature monitor Operating temperature 50 210 C 50 210 C 50 250 C 50 250 C Consistency of temperature 2 C Temperature indication digital Heat up time approx 3 10 min Gross T...

Page 20: ...1 8 Spare Parts TR 60 LCD HT...

Page 21: ...on Temperature monitor Operating temperature 50 210 C 50 210 C 50 250 C Consistency of temperature 2 C Temperature indication digital Heat up time approx 3 10 min Gross Tank Capacity 250 ml Conveying...

Page 22: ...20 Spare Parts TR 700...

Page 23: ...perating temperature 120 C Consistency of temperature 5 C Heat up time approx 3 10 min Gross Tank Capacity 310 ml Conveying system Air pressure Operating pressure 0 5 6 bar Length of electric cord 8 5...

Page 24: ...22 Spare Parts TR 70 LCD HT...

Page 25: ...ion Temperature monitor Temperature indication digital Operating temperature 50 210 C 50 210 C 50 250 C Consistency of temperature 2 C Heat up time approx 3 10 min Gross Tank Capacity 310 ml Conveying...

Page 26: ...24 Spare Parts TR 80 LCD HT...

Page 27: ...or Operating temperature 50 210 C 50 210 C 50 250 C Consistency of temperature 2 C Temperature indication digital Heat up time approx 3 10 min Gross Tank Capacity 310 ml Conveying system Air pressure...

Page 28: ...nsstra e 6 DE 76344 Eggenstein Telephone 49 721 970 780 Telefax 49 721 705 069 E Mail sale reka klebetechnik de Internet http www reka klebetechnik de www pakarte com TR 50 4 25 TR 55 LCD TR 60 LCD TR...

Reviews: