background image

1

CN2

2010

INSTALLATION  INSTRUCTIONS  FOR THE  TIME  AND

TEMPERATURE  CONTROL  with  REMOTE CONTROL

MODELS  JR-1,  JR-2,  JR-3,  JR-4

 

Before commencing with these instructions, ensure that the RELAX-A-MIST

TM

 steam generator has been installed according

to the steam generator installation instructions. 

1.  GENERAL  INFORMATION  

The RELAX-A-MIST

TM

 time and temperature control is a

simple programmable control.   The user friendly design
has programmable time and temperature settings.  Once
a program is set and running, you may temporarily over
ride  the  settings  by  pressing  the  time  or  temperature
buttons  and  pushing  the  applicable  increment  arrow.
Upon  completion  of  the  timed  setting,  or  halting  your
steam bath with the “on/off” button, your temporary over
ride setting will return to the programmed default settings.
Your steam bath is ready for your next use.  Power supply
interruptions  will  not  change  or  delete  your  default  time
and temperature settings. 

The  digital  time  and  temperature  control  comes  as  a
package complete with the following:

1.  One programmable time and  temperature control.

2.

One remote control.

3.

One  25  foot  cord  set  (steam  generator  connection
wire  to  control)  with  a    modular  male  plug-in  at  the
steam unit and a modular female plug-in at the control
in the steam shower or steam room.

The  programmable time and temperature control must be
located inside the steam room, approximately 4 feet off
the finished floor and NOT in an area above the steam
nozzles.  The thermostat sensor is built into the bottom of
the control.  The remote control can only operate the main
control from a direct line of site.

NOTE: Inside of the steam room, the six  inch wire on the

back of the Time & Temperature control (with the male
plug), connects into the 25 foot wire (with the female plug).
At the steam  generator, the male plug from the 25 foot
wire connects to the female plug located on the side of the
steam  generator’s  electrical  box  marked  “Timer  Switch
and 24 VAC”.  The cord set modular female connection
must be identified at the steam generator (do not plug the
switch  cord  into  the  automatic  drain  connection).    The
control’s 25 foot cord set wire must be installed during the
rough in, with the male end at the steam generator and
the female end at the area in the steam bath where the
control will be installed on the wall.

2.  ROUGH IN
ELECTRICAL

 (According to local electrical code)

Check to ensure that the  Relax-A-Mist

TM

 steam

generator has been installed according

LR42682

to the steam  generator installation  instructions.

Install  only  the 

RELAX-A-MIST

TM

  25  foot  cord  set  wire

(compatible with the Quick Touch Timer or the Time and
Temperature Control) ensuring that the modular male plug
is located in the area where the steam generator is to be
installed.  The modular female connector of the 25 foot
wire should protrude out of the wall about 6 inches into the
shower or steam room where the control will be installed.
You will need to make the hole in the cement board and
the finished tile approx. 7/8" diameter to allow the modular
wire connectors from the control and the 25 foot cord set
to pass back inside the wall for the final installation.  DO
NOT ADHERE CONTROL TO WALL UNTIL YOU HAVE
COMPLETED  THE  STEAM  GENERATOR  START  UP
AND CONTROL PRETEST.  
   

CAUTION

      CAUTION

CAUTION:

DO  NOT  STRETCH  WIRE  TIGHT.    DO  NOT  STAPLE
THE  WIRE    TO  STUDS.    CHECK  ORIENTATION  OF
MODULAR CONNECTORS ON CONTROL CORD SET.

NOTE:

The  electrical  "supply"  for  the steam generator
CANNOT  be  switched  directly  by  the  time  and
temperature control

.

Summary of Contents for JR-1

Page 1: ... wire on the back of the Time Temperature control with the male plug connects into the 25 foot wire with the female plug At the steam generator the male plug from the 25 foot wire connects to the female plug located on the side of the steam generator s electrical box marked Timer Switch and 24 VAC The cord set modular female connection must be identified at the steam generator do not plug the swit...

Page 2: ... can not warrant information given regarding steam room materials or construction techniques Final selection of the steam room temperature setting and duration of stay is at the discretion of the operators or owners STEAM GENERATOR START UP and CONTROL PRETEST To start make sure that the electrical and water supplies are turned off and that the programmable switch is not illuminated Turn on the wa...

Page 3: ...ram settings can only be changed when they are flashing When the count down time is complete the display will change to the 3 red bars and the steam generator will shut off You may halt your steam bath program at any time by pushing the on off button Quick Tips For User s Touch the on button displays steam room temp temp shut off setting time in minutes and arrows time up down Touch the temp butto...

Page 4: ...ract or in tort from any cause whatsoever including failure to follow the Relax A Mist installation instructions specifically careless handling improper voltage supply corrosion and or electrolysis or a buildup of minerals on the parts or assemblies for any reason or from any source nor for transportation and or other charges incurred in the removal replacement or repair of defective products or p...