Description of the most important menus 

 

Readout of all: 

This entry reads all meters according to the list of slaves and displays their data. For 
each meter its baud rate and primary or secondary address is used for communication. 
 

Single readout: 

The readout of single meters also uses information from the list of slaves. The submenu 
shows the list with the information of position, primary address and ID. The meter will be 
read after moving the cursor to the desired position and pressing the E button. 
 

Automatical generation of the list of slaves: 

The automatical search for installed meters with generation of the list of slaves is 
started from the menu entry “List of slaves   AutomaticSearch” with the E key. The C 
button cancels the current part of search and jumps to the next search step. Especially 
searching with 300 baud takes much time. You should select just the needed baudrates 
from the menu “Display config. – Highest baudrate / Lowest baudrate” to avoid 
unnecessary long search times. It is also possible to limit the serch to primary or 
secondary addressing using the menu “Display config.   Search mode”. At the end or 
the search the display shows the number of detected meters. You should check the 
entries of the list of slaves from the menu “List of slaves- Show/edit list”.  
 

Editing the list of slaves: 

The entries in the list of slaves can also be edited by the user using the menu “List of 
slaves – Show/edit list”. Move the cursor to the desired position and start the edit mode 
with the E key. You can change the chars with the 

 button and step to the next position 

with the 

 button. The E key confirms and the C key cancels editing. The changes 

affect only the list of slaves, but not the meter options itself. Editing entries is useful if a 
meter has been exchanged. It is also possible to add new meters from the meu “List of 
slaves – Add slave” or to delete single meters from the submenu “

 

 

Setting up baud rates: 

On delivery the M-Bus Display / Datalogger is confiured to search with all supported 
baudrates: 300, 2400 and 9600 bd. You can accelerate the search procedure by limiting 
the search baudrates with “Display config.   Highest baudrate” and “ Lowest baudrate” . 
 

Implemented elements of protocol and data types 

The device includes no meter-specific interpretation, but accepts all meters with a M-
Bus telegram according to the documentation of the M-Bus Usergroup and the 
European standard EN1434-3, which fulfill the following demands: 

• 

Variable data structure (mode 1) or fixed data structure (mode 1 or mode 2) 

• 

Number formats:  Integer (8bit, 16bit, 24bit, 32bit, 48bit, 64bit) 

Real (32bit) 
BCD (2digit, 4 digit, 6digit, 8digit, 12 digit, 16digit) 

Summary of Contents for MR004C

Page 1: ...es Article no MR004C Level converter for 60 unit loads in housing for DIN rail MR04W Level converter for 60 unit loads in wall mountable housing MR004FA Remote display and level converter for 60 unit...

Page 2: ...Datalogger MR004DL Both devices can be operated as a transparent level converter and as a remote display with keyboard or by remote control The datalogger adds the possibility to automatically read a...

Page 3: ...ceive of PC RS485 S S Terminals for RS 485 interface observe polarity M Bus M M M Bus terminals 3 pairs M Bus devices are wired polarity independent in parallel to the same line The signs mark only th...

Page 4: ...s active Handshake unused Pin 1 6 and 9 are not connected RS485 interface The PW60 normally activates the receive mode on the RS485 On reception of data from the M Bus slaves it switches to transmit m...

Page 5: ...he number of connected meters You can connect 60 meters specified with 1 unit load 1 5mA but only 30 meters specified with 2 unit loads 3mA Are there defective slaves or open cable ends lying in the e...

Page 6: ...loads with power Technical data Supply Voltage 230VAC 50Hz 25W respective 110VAC 50Hz 25W US version Environment Operating temperature 0 45 C Storage temperature 10 60 C Humidity 10 70 non condensing...

Page 7: ...he cable diameter The maximum allowed resistance of the cable RL between the MR004DL FA can be estimated with the following formulas N no of unit load each 1 5mA N slaves at end of cable RL 9467 15 x...

Page 8: ...ith LEDs under the terminal lid compartment and also on the LCD If there are problems with interpretation of the M Bus data the display shows Status Error The list of errors is shown on the LCD after...

Page 9: ...ng Fservice the device includes 4 keys and a backlighted display for comfortable local access to all functions The buttons give a very precise mechanical feedback and each input is acknowledged by an...

Page 10: ...activated temporary or permanent error bist in the Status byte an E will be shown The first character follows one digit for the device 0 main device Filtering data To make the readout of data easy th...

Page 11: ...ed to these functions Shows the list of slaves Allows editing of Primary address ID and baudrate The meter data of all devices are read and displayed on the LCD based on the list of slaves After selec...

Page 12: ...YY Shows the ID of location description Change of passcode B global access Selects passcode mode Standard requests passcode on startup Access by ID Adr requests ID address for single read Manually sta...

Page 13: ...tected meters You should check the entries of the list of slaves from the menu List of slaves Show edit list Editing the list of slaves The entries in the list of slaves can also be edited by the user...

Page 14: ...upport this format Therefore we offer a special solution called M Bus modem for use with any level converter and also with MR004DL FA in level converter mode In spite of this the command mode makes us...

Page 15: ...ll with data In this example there is enough memory to store minimum 7 x 65536 5462 83 readouts The practice shows that usualy there are often installations with less meters and shorter M Bus telegram...

Page 16: ...rminal and connect the PC to the modem Choose 9600 baud 8 data bits no parity and one stopbit Then input the following commands each activated by the Enter key Command Function AT for baudrate detecti...

Reviews: