User manual MR004DL/FA 

07.03.02, Version 1.2 

 

GmbH, Stettiner Str. 38, D-33106 Paderborn

Access by ID: 

The M-Bus Display support a different setup of the passcode mode from 

the menu „Display config. – Passcode mode“. If this mode is activated, the user (tenant) 
can make a readout limited to his own meter(s). After first key-press the tenant is 
requested to type in the ID (identification no.) of the required slave. Afterwards this 
single meter is read and its data displayed. Please note that only meters which support 
secondary addressing are readable in this mode. The access to the menu is additionally 
possible in this mode after input of the ID 00000000 and login with the described 
passcodes.  

Access by Adr: 

This mode allows a direct readout of meters using their primary 

addresses without any login procedure. This mode is similar to “Access by ID”. The 
primary address for global readout 254 is used by default. So by just pressing the E key 
you can read a meter if it’s there is only one meter connected. The cursor keys allow 
editing the address. You can leave the input mask and step to the passcode request by 
pressing 3-times the 

 key .  

4 Keyboard operation of MR004FA/MR004DL 

Basics: 

Besides the control using Fservice the device includes 4 keys and a backlighted display 
for comfortable, local access to all functions. The buttons give a very precise, 
mechanical feedback and each input is acknowledged by an acoustic signal (beep). 
Execution of menu entries and input of numbers are described later. The device 
automatically returns to inactive state after some minutes with no input. 
 

Selection of a menu entry: 

An arrow marks the active menu entry on the LCD. The arrow is moved down with the 

 

key and up with the 

 key. Pressing the E button executes the current, selected menu 

entry. The C button cancels the input and exits from the menu. 

                    

 key 

 

Input of numbers: 

The 

 button increments the number of the active position by one. After the 0 ist restarts 

with the 9 again. The 

 key moves the cursor to the next position on the right. The 

active position is blinking. After pressing 

 at the most right digit the cursor moves to 

the most left digit. The E button ends and acknowledges the input regardless of the 
current position. You can cancel the input with the C key. 

After input of passcode and confirming with the E key the main 
menu is activated. You can see always two entries of this 
menu. The first displayed lines are “Readout of all” and “Single 

 button the LCD scrolls to the next 

part of the menu. In this example the line “Single readout” will 
then be marked with the arrow. This submenu would be entered 
with the E key. 

Summary of Contents for MR004C

Page 1: ...es Article no MR004C Level converter for 60 unit loads in housing for DIN rail MR04W Level converter for 60 unit loads in wall mountable housing MR004FA Remote display and level converter for 60 unit...

Page 2: ...Datalogger MR004DL Both devices can be operated as a transparent level converter and as a remote display with keyboard or by remote control The datalogger adds the possibility to automatically read a...

Page 3: ...ceive of PC RS485 S S Terminals for RS 485 interface observe polarity M Bus M M M Bus terminals 3 pairs M Bus devices are wired polarity independent in parallel to the same line The signs mark only th...

Page 4: ...s active Handshake unused Pin 1 6 and 9 are not connected RS485 interface The PW60 normally activates the receive mode on the RS485 On reception of data from the M Bus slaves it switches to transmit m...

Page 5: ...he number of connected meters You can connect 60 meters specified with 1 unit load 1 5mA but only 30 meters specified with 2 unit loads 3mA Are there defective slaves or open cable ends lying in the e...

Page 6: ...loads with power Technical data Supply Voltage 230VAC 50Hz 25W respective 110VAC 50Hz 25W US version Environment Operating temperature 0 45 C Storage temperature 10 60 C Humidity 10 70 non condensing...

Page 7: ...he cable diameter The maximum allowed resistance of the cable RL between the MR004DL FA can be estimated with the following formulas N no of unit load each 1 5mA N slaves at end of cable RL 9467 15 x...

Page 8: ...ith LEDs under the terminal lid compartment and also on the LCD If there are problems with interpretation of the M Bus data the display shows Status Error The list of errors is shown on the LCD after...

Page 9: ...ng Fservice the device includes 4 keys and a backlighted display for comfortable local access to all functions The buttons give a very precise mechanical feedback and each input is acknowledged by an...

Page 10: ...activated temporary or permanent error bist in the Status byte an E will be shown The first character follows one digit for the device 0 main device Filtering data To make the readout of data easy th...

Page 11: ...ed to these functions Shows the list of slaves Allows editing of Primary address ID and baudrate The meter data of all devices are read and displayed on the LCD based on the list of slaves After selec...

Page 12: ...YY Shows the ID of location description Change of passcode B global access Selects passcode mode Standard requests passcode on startup Access by ID Adr requests ID address for single read Manually sta...

Page 13: ...tected meters You should check the entries of the list of slaves from the menu List of slaves Show edit list Editing the list of slaves The entries in the list of slaves can also be edited by the user...

Page 14: ...upport this format Therefore we offer a special solution called M Bus modem for use with any level converter and also with MR004DL FA in level converter mode In spite of this the command mode makes us...

Page 15: ...ll with data In this example there is enough memory to store minimum 7 x 65536 5462 83 readouts The practice shows that usualy there are often installations with less meters and shorter M Bus telegram...

Page 16: ...rminal and connect the PC to the modem Choose 9600 baud 8 data bits no parity and one stopbit Then input the following commands each activated by the Enter key Command Function AT for baudrate detecti...

Reviews: