Compressed  air 

contains  liquid  water  and  is  saturated  with  water  vapor,  which  can 

freeze when surrounding temperatures are lower than 32

o

F (0

o

C). Component selection 

to minimize the effects of water vapor must be  considered. 

- Do not touch any component inside compressor enclosure or on the discharge piping 
when the compressor is operating or immediately after it has stopped. The components 
are  extremely  hot  and  can  cause  severe  injury.  Before  servicing  the  compressor, 
disconnect the power and wait for its components to cool down. 

 

Section 2 - Receiving

 

Your  compressor  is  inspected  at  the  factory  and  packaged  to  protect  against  shipping  damage.  When  the  compressor  is 
unpacked, inspect for damage or missing parts. All claims should be settled directly with the freight company. 

 

-  Do  not  operate  this  compressor  if  damaged  during  shipment,  handling  or  use.  Any 
damage may result in failure and cause injury or property damage. 

 

 

Section 3 - Installation Location 

Locate the compressor in a clean, well ventilated area where air is relatively cool, clean and dry. A 104°F (40°C) maximum 
and  40°F  (4°C)  minimum  temperature  for  surrounding  and  inlet  air  are  recommended.  Provide  at  least  12  to  18  inches  of 
clearance from any wall or other obstruction that will interfere with airflow over and through the compressor. Blocking airflow 
through the fan may cause the compressor to overheat. Do not place the compressor in an area of excessive heat, such as 
near a boiler. 

 

Section 4 - Mounting 

4.1 General Information 

QRM2-  Series  Riser  mounted  units  may  be  mounted  to  a  fire  sprinkler  system  riser  with  a  riser  mounting  bracket.  A  riser 
mounting bracket and (3) straps are provided. Both tank and tank-less riser mounted units should be connected with a flex 
hose (Ordered Separately). The flex  hose (P/N 6872000000) must be installed between the compressor or  tank outlet and 
service piping. 

The compressor must be mounted in 

a flat, level, horizontal orientation. The “L” shaped bracket is provided to ensure this. The 

compressor is shipped mounted to the “L” bracket using rubber mounts. This can then be directly mounted and fastened to 
the flat riser bracket provided with straps. 

 

 

WARNING

 

WARNING

 

WARNING

 

Summary of Contents for QRM2 Series

Page 1: ...ank Mounted Quiet Oil less Air Compressors Installation Operation and Maintenance Manual For 60Hz Models Only Reliable Automatic Sprinkler Co Inc 103 Fairview Park Drive Elmsford New York 10523 800 55...

Page 2: ...Instruction QRM2 Mounting Bracket Section 5 Lubrication Section 6 Piping 6 1 Piping Instructions 6 2 QRM2 Series Riser Mounted Quiet Oilless Air Compressor Installation Drawing 6 3 QRM2 T Series Tank...

Page 3: ...ment 2 Follow all local electrical and safety codes as well as National Electrical Codes NEC Occupational Safety and Health Act OSHA and National Fire Protection Association NFPA 3 Only persons famili...

Page 4: ...an well ventilated area where air is relatively cool clean and dry A 104 F 40 C maximum and 40 F 4 C minimum temperature for surrounding and inlet air are recommended Provide at least 12 to 18 inches...

Page 5: ...n IMPORTANT NOTE Torque straps screws to 35 to 40 in lbs 4 3 Basic Instructions QRM2 Mounting Bracket 1 2 Use the rectangular holes on the bracket to rest it on the riser plate hooks A B C D Securely...

Page 6: ...re at the AMD is 200 F or less An AMD must be used with all riser mounted tank units All oilless compressors include a relief valve which is installed on the compressor This valve will open at a prese...

Page 7: ...6 Section 6 Piping 6 2 QRM2 Series Riser Mounted Oilless Air Compressor Installation Drawing...

Page 8: ...7 6 3 QRM2 T Series Tank Mounted Oilless Air Compressor Installation Drawing...

Page 9: ...ed on a 100 run and lowest operating voltage Consult factory for longer runs Single phase motors include internal thermal overload protection which has an automatic reset device Disconnect electrical...

Page 10: ...9 7 2 Oilless Air Compressor Single Phase Wiring Drawing...

Page 11: ...with Tank RASCO Part Number 6990021905 Factory Set at 50 PSIG Cut IN 70 PSIG Cut OUT QRM2 Models without Tank RASCO Part Number 6990021904 Factory Set at 20 PSIG Cut IN 26 PSIG Cut OUT Differential P...

Page 12: ...lower voltage drop 2 Replace compressor 3 Replace check valve 4 Repair or replace pressure switch Reset mechanism cuts out or fuses blow repeatedly 1 Insufficient voltage to motor 2 Pressure switch se...

Page 13: ...EXCEPT AS TO TITLE THE COMPANY MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY THE REMEDY PROVIDED UNDER THIS WARRANTY SHALL BE THE SOLE E...