Section 7 - Wiring  

7.1 Wiring Instructions 

- Wiring should be in accordance with the National Electrical Code (NEC) and any local 
codes or regulations. Have a licensed and competent electrician ensure that the voltage 
supplied matches the compressor voltage. 

- Inadequate wiring size can cause insufficient voltage at the compressor during start-up. 
Overheating and damage can result to the motor and controls. 

- Failure to use the pressure switch may result in overpressure of the compressor or other 
components  in  the  system.  Overpressure  of  the  compressor  can  result  in  blown  head 
gaskets or other damage. 

-  Grounding  Instructions:  This  product  must  be  connected  to  a  grounded,  metallic, 
permanent wiring system, or an equipment grounding terminal or lead on the product. 

 

The supply wire must be of adequate size and no other equipment should be connected 
to the same  line. The  adjacent table lists the recommended wire size for  each  model 
based on a 100’ run and lowest operating voltage. Consult factory for longer runs. 

 

-  Single-phase  motors  include  internal  thermal 
overload protection, which has an automatic reset 
device. 

-  Disconnect  electrical  power  before  servicing  to 
disable  reset  devices.  Thermal  protection  can 
automatically  start  the  motor  when  the  protector 
resets. 

 

 

The motor is pre-wired to the pressure switch provided, which controls starting (cut-in pressure) and stopping (cut-out 
pressure) of the motor. The pressure switch is factory set. Tank-less riser mount models have the switch set at 20 cut-in and 
26 psig cut-out. Riser Mount with Tank have the switch set at 50 psig cut-in and 70 psig cut-out. 

 

A motor starter can be used, for all single phase models. 

Consult the National Electric Code and local codes for motor 

starter requirements. Refer to the proper wiring instruction drawing for recommended wiring to a starter. 

 

 

 

Minimum Recommended Wire Size

 

 

60Hz Model # 

 

1 Phase

 

QRM2-25115 

12 

QRM2-25220 

12 

QRM2-25115T 

12 

QRM2-25220T 

12 

QRM2-50115 

12 

QRM2-50220 

12 

QRM2-50115T 

12 

QRM2-50220T 

12 

QRM2-100115T 

12 

QRM2-100220T 

12 

WARNING

 

CAUTION

 

NOTICE

 

NOTICE

 

NOTICE

 

WARNING

 

Summary of Contents for QRM2 Series

Page 1: ...ank Mounted Quiet Oil less Air Compressors Installation Operation and Maintenance Manual For 60Hz Models Only Reliable Automatic Sprinkler Co Inc 103 Fairview Park Drive Elmsford New York 10523 800 55...

Page 2: ...Instruction QRM2 Mounting Bracket Section 5 Lubrication Section 6 Piping 6 1 Piping Instructions 6 2 QRM2 Series Riser Mounted Quiet Oilless Air Compressor Installation Drawing 6 3 QRM2 T Series Tank...

Page 3: ...ment 2 Follow all local electrical and safety codes as well as National Electrical Codes NEC Occupational Safety and Health Act OSHA and National Fire Protection Association NFPA 3 Only persons famili...

Page 4: ...an well ventilated area where air is relatively cool clean and dry A 104 F 40 C maximum and 40 F 4 C minimum temperature for surrounding and inlet air are recommended Provide at least 12 to 18 inches...

Page 5: ...n IMPORTANT NOTE Torque straps screws to 35 to 40 in lbs 4 3 Basic Instructions QRM2 Mounting Bracket 1 2 Use the rectangular holes on the bracket to rest it on the riser plate hooks A B C D Securely...

Page 6: ...re at the AMD is 200 F or less An AMD must be used with all riser mounted tank units All oilless compressors include a relief valve which is installed on the compressor This valve will open at a prese...

Page 7: ...6 Section 6 Piping 6 2 QRM2 Series Riser Mounted Oilless Air Compressor Installation Drawing...

Page 8: ...7 6 3 QRM2 T Series Tank Mounted Oilless Air Compressor Installation Drawing...

Page 9: ...ed on a 100 run and lowest operating voltage Consult factory for longer runs Single phase motors include internal thermal overload protection which has an automatic reset device Disconnect electrical...

Page 10: ...9 7 2 Oilless Air Compressor Single Phase Wiring Drawing...

Page 11: ...with Tank RASCO Part Number 6990021905 Factory Set at 50 PSIG Cut IN 70 PSIG Cut OUT QRM2 Models without Tank RASCO Part Number 6990021904 Factory Set at 20 PSIG Cut IN 26 PSIG Cut OUT Differential P...

Page 12: ...lower voltage drop 2 Replace compressor 3 Replace check valve 4 Repair or replace pressure switch Reset mechanism cuts out or fuses blow repeatedly 1 Insufficient voltage to motor 2 Pressure switch se...

Page 13: ...EXCEPT AS TO TITLE THE COMPANY MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY THE REMEDY PROVIDED UNDER THIS WARRANTY SHALL BE THE SOLE E...

Reviews: