26
Controller Performance
D
Efficiency (at rated speed and load):
- Controller 97%
- Controller and motor 78%
D
Displacement power factor (at rated speed and load): 70%
Table 24. Controller Ratings by Motor Horsepower.
Rated
AC Line
Amperes
DC
Armature
Voltage
Rated
Armature
Current
(amperes)
Available
Field
Voltage
Available
Field
Current
(amperes)
1/4
1/3
1/2
3/4
1
11/2
2
3.1
4.2
6.2
9.4
12.5
3.1
4.7
6.2
9.4
12.5
.36
.48
.71
1.00
1.40
.71
1.00
1.40
2.20
2.90
90
90
90
90
90
180
180
180
180
180
2.5
3.7
5.0
7.5
10.0
2.5
3.7
5.0
7.5
10.0
50
50
50
50
50
100
100
100
100
100
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1
1
Includes motor field current.
115Volt AC Input
230Volt AC Input
Motor
HP
Input
KVA
2
DC250, 52, 53, 54, 55 and 56 plate design controllers must be mounted to a
metal plate 18" x 18" to meet 1 HP @ 115 VAC and 2 HP @ 230 VAC ratings,
or an optional heatsink (model number HS150) can be purchased.
2
2
Table 25. Controller Isolation Transformer Ratings
HP
1/4
1/3
1/2
3/4
1
11/2
2
Transformer KVA
0.75
1.50
2.00
3.00
5.00
0.75
1.50
Summary of Contents for DC2 VS series
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ......
Page 31: ...3 16 419 519 TB2 Motor Mounted D C Tachometer Figure 3 8 D C Tachometer Connection...
Page 48: ...5 6 Figure 5 1 Wiring Diagram of Basic Speed Controller 0 57210 30...
Page 49: ...5 7...
Page 51: ...5 9 J4...