43
NOTE
: Rotate jumper 90
_
to select 5, 20, or 50 mA input signals.
2
4
6
1
3
5
(50mA) (20mA) (5mA)
J201: Minimum Speed Disable
WARNING
THE DRIVE IS INTENDED TO OPERATE AT A PREDETERMINED MINIMUM
SPEED UNLESS DISCONNECTED FROM THE POWER SOURCE. IF THE
APPLICATION REQUIRES ZERO SPEED OPERATION WITHOUT SUCH DIS
CONNECTION, THE USER IS RESPONSIBLE FOR ASSURING SAFE CONDI
TIONS FOR OPERATING PERSONNEL BY PROVIDING SUITABLE GUARDS,
AUDIBLE OR VISUAL ALARMS, OR OTHER DEVICES. FAILURE TO OBSERVE
THIS PRECAUTION COULD RESULT IN BODILY INJURY.
NOTE:
A jumper (Reliance part # 40550469D) is provided in a plastic
bag shipped with the drive.
1. Place the jumper on position J201.
2. Turn MIN SPEED potentiometer fully counterclockwise to obtain
zero minimum speed.
J202: SCurve Acceleration
NOTE:
A 4.7
m
FD (Reliance part #6938051PS) capacitor is provided in
a plastic bag shipped with the drive.
1. Attach the capacitor to J202 (pins 1 and 2) if SCurve acceleration
characteristics are desired.
J203: Regulation Mode Jumper
NOTE:
Do not move this jumper on 05721030 Regulator Boards.
1. For Voltage/Speed regulation, place jumper on pins 2 and 4.
2. For Torque regulation, place jumper on pins 1 and 3.
J401: Rate Range Jumper
(On 05721031 and 05721032 Regulator Boards
only)
NOTE:
This jumper is factory set for the slow rate range (upper and
middle pins). The slow rate range is 3.5 to 40 seconds.
1. Select the fast rate range for better resolution. To select the fast rate
range (0.3 to 3.5 seconds), move this jumper to the lower and
middle pins.
Summary of Contents for DC2 VS series
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ......
Page 31: ...3 16 419 519 TB2 Motor Mounted D C Tachometer Figure 3 8 D C Tachometer Connection...
Page 48: ...5 6 Figure 5 1 Wiring Diagram of Basic Speed Controller 0 57210 30...
Page 49: ...5 7...
Page 51: ...5 9 J4...