background image

Troubleshooting Guidelines  

(Contact Remco for troubleshooting)

IF PUMP WILL NOT START CHECK:

 

y

Correct voltage (±10%) and electrical connections

 

y

Fuse or breaker

 

y

Pressure switch operation and correct voltage at switch

 

y

Rectifier or motor for open or grounded circuit

IF PUMP WILL NOT PRIME (NO DISCHARGE WITH MOTOR RUNNING) CHECK:

 

y

Debris in strainer

 

y

Restriction (kinks) in inlet/outlet tubes

 

y

Debris in inlet/outlet 

 

y

Air leaking in from inlet

IF PUMP WILL NOT SHUT OFF (OUTPUT LINE CLOSED AND NO LEADS) CHECK:

 

y

Air trapped in outlet line or pump head

 

y

Correct voltage to pump

 

y

Debris in pump inlet/outlet valves

 

y

Loose drive assembly or pump head screws

 

y

Pressure switch operations/adjustments

 

y

Leaks

IF PUMP LEAKS FROM PUMP HEAD OR SWITCH CHECK:

 

y

Loose screws at switch or pump head

 

y

Switch diaphragm ruptured or pinched

 

y

Punctured diaphragm if fluid is present

Warranty

REMCO warrants its products to be free from defects in material and workmanship on all products 

sold by REMCO for resale or for use in purchasers’ own business or original equipment  

manufacturer. Under normal use, maintenance, and service (rental use excluded), the following 

terms apply: For REMCO SmoothFlo® products, the warranty will last for a period of 90 days for 

commercial use from the date of purchase by the user. This warranty applies to the original purchaser 

of the equipment and is non-transferrable. Verification of the purchase is the responsibility of the 

buyer. REMCO’s obligation under this warranty shall be limited to replacing or repairing at REMCO’s 

discretion, any such product or part which must be returned to REMCO’s factory with a Return Material 

Authorization Number (RMA), transportation charges approved by REMCO or prepaid, and which 

upon examination, is found to REMCO’s satisfaction to have been defective under the terms of this 

warranty. No credit will be allowed against future purchases for items returned as defective under the 

terms of REMCO’s warranty. This warranty does not extend to any products, which have been altered 

or modified outside the REMCO factory, to any products that have not been properly maintained, nor 

does it apply to units that are returned in an unassembled condition. Furthermore, the warranty does 

not extend to pumps that are non-compliant with REMCO’s Engineering Standards. This includes, 

but is not limited to, pumps ordered without an integral pressure control mechanism. The warranty 

guarantees that products will perform to REMCO’s flow and pressure specifications throughout the 

life of the warranty. The warranty does not cover wear, appearance, misuse, abuse, misapplication or 

external water damage. If the returned product is found not to be defective under the conditions of this 

warranty, a charge will be made for repair or replacement of the product.
Brush wear may be limited to 1000 hours or less. 
This is a Limited Warranty. It covers the product only and the extent of the coverage is limited to the 

cost of the product. As the manufacturer has no control over shipping, handling and  

installation, the warranty cannot cover water damage, or any other damage, caused by a leak or other 

malfunction.
THIS WARRANTY IS IN LIEU OF ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING IMPLIED 

WARRANTIES OR WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. 

NO PERSON IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR ASSUME OBLIGATION OR LIABILITY 

ON REMCO’S BEHALF. REMCO SHALL NOT BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE OR 

CONSEQUENTIAL DAMAGES OF ANY KIND INCURRED BY THE REASON OF THE USE OR SALE OF ANY 

DEFECTIVE PRODUCT AND PART. THIS WARRANTY SHALL BE GOVERNED BY THE LAWS OF THE STATE OF 

MINNESOTA, WITH ANY DISPUTE OR CLAIM VENUED OR HEARD IN THE STATE OF MINNESOTA.

Replacement Parts

1

www.remcoindustries.com 

SmoothFlo Manual - 2022

1

PART NUMBER GPM

DESCRIPTION

5917-9I77

5.3 GPM

SmoothFlo Series, 100 PSI, 3/4” Quick Attach

5918-9I77

7.0 GPM

SmoothFlo Series, 100 PSI, 3/4” Quick Attach

Complete Pumphead Assembly

*When being used in soft wash applications, SmoothFlo pumps need to be flushed with clean water at the of the day*

Reviews: