8
Trimmer blades do not move:
•
The cutting unit may be dirty and clogged.
• Clean and lubricate the unit.
BATTERY REMOVAL
• The battery must be removed from the appliance before it is scrapped.
• The appliance must be disconnected from the mains supply when removing
the battery.
• Turn the trimmer on and discharge all remaining power.
• Remove the comb and cutter assembly.
• Use a screwdriver to pry out the holder plate under the trimmer carefully.
• Use a screwdriver to pry the two side panels carefully.
• Remove the 4 screws from the housing.
• Using a screwdriver carefully pry apart the top and bottom housing.
• Unscrew the 2 screws on the circuit board.
• Remove the upper circuit board.
• Disconnect the battery from the low circuit board.
• The battery is to be disposed of safely.
RECYCLING
W
To avoid environmental and health problems due to hazardous
substances, appliances and rechargeable and non-
rechargeable batteries marked with one of these symbols must
not be disposed of with unsorted municipal waste. Always
dispose of electrical and electronic products and, where
applicable, rechargeable and non-rechargeable batteries, at an
appropriate official recycling/collection point.
ENGLISH