9
119586
WATER
S
F
3. aLWaYS
use the spall shield when driving directly into
concrete or steel.
aLWaYS
wear eye protection.
4. nEVEr
use a powder actuated tool in an explosive or
flammable atmosphere or when non-sparking tools are
required.
pOWEr LOaDS anD pOWEr FaStEnErS
1. nEVEr
leave unfired power loads on floors or work surfaces.
2.
Should the tool fail to fire, hold the muzzle firmly against
the work surface for 30 seconds. Release the trigger and
remove pressure on the tool while holding the muzzle
against the work surface. Again press the tool firmly against
the work surface and pull the trigger. If the tool still fails to
fire, hold the tool firmly against the work surface for another
30 seconds before unloading and carefully discarding the
misfired power load into water or oil.
30
S
F
S
F
Spall
Shield
Safety precautions
S
F
GASOLINE
GAS
OLINE
pOWEr
LOaDS
pOWEr