Set the operating switch to
the position „0“ (Off).
In case of longer
standstills, disconnect
the equipment from
the power mains.
The condensate container must
be emptied and dried with a clean
cloth.
Pay attention to dripping conden-
sate!
For storage purposes, the units
should be covered with plastic/
sheeting and stored in an upright
position in a protected and dry
location.
The units can be stacked one on
top of the other for space-saving
storage.
For this purpose, they are provided
with special rubber pads on the
base plate.
Variant A
The water is collected in a suffi-
ciently large dimensioned container
to be provided locally.
The container
must
be checked
regularly and emptied as necessary.
No overflow protection is pro-
vided!
Variant C
The water flows via a hose into a
lower located drain.
This variant enables unsupervised
continuous duty.
Condensate drain AMT 110-E
AMT 110-E units are not provided with an internal condensate container
due to their high dehumidification capacity.
Condensate discharge must take place locally into suitable containers or
via the external unit connection.
The following variants are available for discharge of the produced con-
densate water:
Variant B
The water is initially collected in a
container and pumped to a raised
outlet or to the outside via a sepa-
rate submersible pump.
This variant is suitable for installa-
tion sites without sufficient gradi-
ent or without drain.
Shutdown
nOTE
These described variants can be used analogous also for all other
unit types for continuous condensate discharge.
CAuTIOn
The units must be secured
after stacking to prevent them
falling over and against unau-
thorised access.
12
REMKO AMT