background image

13

No.

Designation

DZH 30-2 DZH 50-2

EDP-No.

EDP-No.

01 Combustion chamber, cpl. 1111690 1111705

02 Inspection cover

1111691 1111706

05 Intake guard grille

1111692 1111707

06 Fan blade

1111693 1111708

07 Fan housing

1111694 1111709

08 Fan motor, complete

1111695 1111710

09 Motor carrier

1111696 1111711

10 Capacitor

1107160 1107174

12 Tank cap

1102148 1102148

13 Tank filter

1103776 1103776

14 Suction tube

1111697 1111712

15 Connecting nipple

1111667 1111667

17 Protective cap

1107122 1107122

18 Transport stirrup

1107163 1111713

19 Stand stirrup

1107164 1107164

20 Sealing ring/Drain plug

1103777 1103777

21 Drain plug

1103778 1103778

22 Fuel tank

1111699 1111714

23 Axle

1107166 1107166

24 Wheel

1102155 1102155

25 Hub cap

1101623 1101623

26 Circlip

1101622 1101622

27 Electrical module, cpl.

1107367 1107367

28 Support housing

1111700 1111715

29 Bottom of housing

1111701 1111716

30 Cool-down thermostat

1107182 1107182

31 Fuel pump, complete

1107123 1107123

32 Magnet coil

1103766 1103766

33 Magnet coil core

1111671 1111671

34 Connecting nipple  

pressure line

1111672 1111672

35 Oil pressure line

1111673 1111673

38 GE coupling, complete

1107129 1107129

39 Connecting nipple intake 

line

1111674 1111674

No.

Designation

DZH 30-2 DZH 50-2

EDP-No.

EDP-No.

40 Nozzle

1107126 1111717

41 Nozzle cradle

1107132 1107132

42 Mounting plate

1111675 1111675

43 Nut

1107134 1107134

44 Photoelectric cell mount

1111676 1111676

45 Photoelectric cell 

1108209 1108209

46 Ignition cable with plug

1107137 1107137

48 Ignition electrode

1107139 1107139

50 Auxiliary Relay

1107375 1107375

52 Ignition transformer

1107143 1107143

53 Support plate PE

1107188 1107188

55 Switch cabinet housing

1107189 1107189

56 Operating switch

1111677 1111677

58 Seal housing

1107190 1107190

59 Jumper plug

1101019 1101019

60 Thermostat socket,  

complete

1101018 1101018

62 Mains cable with plug

1107148 1107148

63 Pull relief 

1107149 1107149

64 Sealing ring OR 22

1111678 1111678

65 Automatic burner relay

1102239 1102239

66 Relay socket

1102534 1102534

67 Plate PG

1102533 1102533

68 Relay fitting

1107191 1107191

69 Terminal strip

1103781 1103781

70 Burner pipe

1111702 1111702

71 Protective cap

1111680 1111680

72 Air slide

1111681 1111681

73 Support plate (STB)

1111682 1111682

74 Temperature limiter (STB)

1111683 1111683

76 Suction pipe PF

1111703 1111703

77 Suction pipe TF

1111704 1111704

78 Fuel filter (disposable)

1102146 1102146

79 Hose clamp

1103762 1103762

When ordering spare parts, always list the device number and the device type (see the type plate) in addition to the EDP number.

Spare parts list

 

Summary of Contents for DZH 20

Page 1: ...Edition GB W08 REMKO DZH Oil Heaters Operation Technology Spare Parts ...

Page 2: ......

Page 3: ...8 Contents Subject to change errors and typographical errors excepted Safety Notices 4 Device Description 4 Mounting Regulations 5 Commissioning 6 Shutdown 7 Maintenance and Care 8 Trouble Shooting 9 Exploded view DZH 20 2 10 Spare Parts List DZH 20 2 11 Exploded view DZH 30 2 50 2 12 Spare Parts List DZH 30 2 50 2 13 Exploded view DZH 90 14 Spare Parts List DZH 90 15 Proper Use 16 Customer Servic...

Page 4: ... containing oil sulphur or salt A safety zone of 3 m around the exhaust and 1 m around the unit and non flammable objects must be observed The protective air suction grille must always be free of dirt and loose objects Never insert foreign matters into the unit The unit may not be exposed to direct water jets such as high pressure cleaning unit and so on All electrical cables of the unit must be p...

Page 5: ...ssociations the respective country construction ordinances and the burning appliance regulations basically apply For example for Germany Feuerungsanlagenverordnung FeuVo Furnace Installation Ordi nances of the individual states Unfallverhütungsvorschrift UVV Accident Prevention Regulation Heiz Flämm und Schmelzge räte für Bau und Montagear beiten Heating Burning and Melting Equipment for Construc ...

Page 6: ...mains plug of the device to a properly installed and secured mains socket 230 V 50 Hz CAUTION In case of defects that endan ger the operating safety of the unit the operation of the unit must be shut down immedi ately and the supervisor must be informed CAUTION All cable extensions may be used only when unrolled Paraffin formation at low out door temperatures Even in case of low temperatures free ...

Page 7: ...due to overheating 1 3 Notices regarding the safety cut off of the unit The unit fuel supply takes place in a single line system In this regard the fuel supply to the nozzle can be interrupted by blowing air during the initial start up or after the fuel tank has been completely emptied The automatic burner relay of the appliances shut down due to mal function in this case This shutdown due to malf...

Page 8: ...vicinity of the tank filler neck Note the direction of flow Use only clean EL heating oil or diesel Look for paraffin formation Allow only authorised expert personnel to clean the gauze filter in the fuel pump only by DZH 90 and exchange the nozzle Regularly check the safety appliances for correct function In case of a weakening heating capacity formation of smoke and or bad ignition inspect the u...

Page 9: ...ump and exchange if necessary 9 The fuel container is empty Fill the container with clean fuel 10 The oil filter is stopped up Clean or exchange oil firter 11 The nozzle is stopped up or has the wrong size Exchange the nozzle Pay attention to the right type and size 12 The electrode is incorrectly adjusted die isolation is defective Adjust or exchange it 13 The air inlet plate of the burner head i...

Page 10: ...10 REMKO DZH Exploded view DZH 20 2 We reserve the right to make changes in dimensions and design in the interest of technical advances 24 B A ...

Page 11: ...7131 41 Nozzle cradle 1107132 No Designation EDP No 42 Mounting plate 1111675 43 Nut 1107134 44 Photoelectric cell mount 1111676 45 Photoelectric cell 1108209 46 Ignition cable with plug 1107137 48 Ignition electrode 1107139 50 Auxiliary Relay 1107375 52 Ignition transformer 1107143 53 Support plate PE 1107188 55 Switch cabinet housing 1107189 56 Operating switch 1111677 58 Seal housing 1107190 59...

Page 12: ...12 REMKO DZH 27 B A Exploded view DZH 30 2 50 2 We reserve the right to make changes in dimensions and design in the interest of technical advances ...

Page 13: ...ine 1111674 1111674 No Designation DZH 30 2 DZH 50 2 EDP No EDP No 40 Nozzle 1107126 1111717 41 Nozzle cradle 1107132 1107132 42 Mounting plate 1111675 1111675 43 Nut 1107134 1107134 44 Photoelectric cell mount 1111676 1111676 45 Photoelectric cell 1108209 1108209 46 Ignition cable with plug 1107137 1107137 48 Ignition electrode 1107139 1107139 50 Auxiliary Relay 1107375 1107375 52 Ignition transf...

Page 14: ...8 61 56 54 62 63 52 50 51 81 71 56 1 4 15 16 16 15 17 2 5 A 48 3 7 58 16 8 10 6 9 15 11 20 21 22 29 29 27 24 29 28 39 38 37 30 31 32 36 43 44 25 45 40 35 45 Exploded view DZH 90 We reserve the right to make changes in dimensions and design in the interest of technical advances ...

Page 15: ...07148 43 Impact clamp 1107369 No Designation EDP no 44 Lower cover 1107370 45 Nut 1107371 48 Re cooling thermostat 1107182 50 Swivel disc 1103743 51 Nozzle 1107372 52 Nozzle mounting 1103745 53 Assembly plate 1107373 54 GE screw attachement 1103749 55 Ignition electrode 1103747 56 Ignition cable incl plug 1107137 58 Oil pressure pipe 1107125 61 Screw nut 1107134 62 Photoelectric cell 1108209 63 Ph...

Page 16: ...ng When disposing of the packaging material think of the environment Our equipment is carefully packed for transport and delivered in a stable cardboard transport package on a wooden pallet if necessary The packaging materials are environmentally friendly and can be reused With the reuse of packaging mate rial you make a valuable contribu tion to the reduction of waste and the preservation of raw ...

Page 17: ...erating switch C Condenser FZ Photoelecrtic cell HS Auxiliary relay M Motor MV Solenoid valve 1 2 3 4 5 6 7 8 9 10 11 12 PE L N 230 V 50 Hz BS RS MV FZ ZE ZT M C 2 3 RT NK STB A1 A2 14 11 HS 1 2 3 4 5 6 7 8 N 9 NK Re cooling thermostat RS Relay socket RT Thermostat plug socket STB Safety limiter ZE Ignition electrode ZT Ignition transformer ...

Page 18: ...Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Model Model No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Clean unit surface Clean unit interior Clean fan blade Clean fan housing Clean condenser Clean evaporator Fan function checked Intake grille with filter cleaned Check unit for damage Protective devices checked All fixing screws checked Electrical safety tes...

Page 19: ...er consumption W 200 290 430 690 Fuse protection on site A 10 10 10 10 Noise pressure level LpA 1m 2 dB A 74 77 78 79 Total length mm 800 1050 1090 1400 Total width mm 300 500 500 655 Total height mm 520 615 740 890 Weight kg 21 37 43 84 EDP no 116202 116302 116502 116900 Technical Data We reserve the right to make changes in dimensions and design in the interest of technical advances 1 The said p...

Page 20: ... and abroad but also unusually highly qualified sales experts REMKO sales representatives are more than just salespeople they must also be customer consultants in air conditioning and heating technology Customer care Our devices function precisely and reli ably If a malfunction appears however REMKO Customer Care is on the job Our extensive network of experienced dealers guarantees you constant sh...