No

.

Designation

 

EDP no.

1

Cover

1107350

2

Inspection cover

1107351

3

Combustion chamber cpl.

1107352

4

Temperature limiter (STB)

1107353

5

Air inlet plate

1107354

6

Solenoid coil

1103766

7

Fuel pump cpl.

1103765

8

Hose connection

1102109

9

Pump coupling

1107355

10

Fan motor cpl.

1107356

11

Condenser

1107357

15

Fuel hose

1107104

16

Hose clamp

1103762

17

Fuel filter (one-way)

1102146

20

Air inlet grille

1107358

21

Fan blade

1107359

22

Fan housing

1107360

24

Suction pipe

1107361

25

Mount housing

1107362

27

Transport clamp

1107363

28

Stand clamp

1107364

29

Protection cap

1107365

30

Fuel container

1107366

31

Fuel filter

1103776

32

Tank lock

1102148

35

Electrical set cpl.

1107367

36

Axle

1107368

37

Wheel

1101621

38

Wheel cap

1101623

39

Retaining ring

1101622

40

electrical cable incl. plug

1107148

43

Impact clamp

1107369

No.

Designation

 

EDP no.

44

Lower cover

1107370

45

Nut

1107371

48

Re-cooling thermostat

1107182

50

Swivel disc

1103743

51

Nozzle

1107372

52

Nozzle mounting

1103745

53

Assembly plate

1107373

54

GE screw attachement

1103749

55

Ignition electrode

1103747

56

Ignition cable incl. plug

1107137

58

Oil pressure pipe

1107125

61

Screw nut

1107134

62

Photoelectric cell

1108209

63

Photo cell holder

1301560

65

Strain relief

1107149

70

Auxiliary relay

1107375

71

Ignition transformer

1107143

72

Carrier plate PE

1107188

73

Plug connection

1103781

75

Shunt plug

1101019

76

Thermostat plug socket cpl.

1101018

77

Protection cap

1101189

78

Switch

1102248

80

Control box housing

1107146

81

Seal

1107190

82

Relay

1102239

83

Relay socket

1102534

84

Relay fitting

1107191

xx

Seal for drain screw

1103777

xx

drain screw

1103778

Spare parts list

 

When ordering spare parts, always list the device number and the device type (see the type plate) in addition to the EDP number.

xx = not shown

Summary of Contents for DZH 20

Page 1: ...Edition GB W08 REMKO DZH Oil Heaters Operation Technology Spare Parts ...

Page 2: ......

Page 3: ...8 Contents Subject to change errors and typographical errors excepted Safety Notices 4 Device Description 4 Mounting Regulations 5 Commissioning 6 Shutdown 7 Maintenance and Care 8 Trouble Shooting 9 Exploded view DZH 20 2 10 Spare Parts List DZH 20 2 11 Exploded view DZH 30 2 50 2 12 Spare Parts List DZH 30 2 50 2 13 Exploded view DZH 90 14 Spare Parts List DZH 90 15 Proper Use 16 Customer Servic...

Page 4: ... containing oil sulphur or salt A safety zone of 3 m around the exhaust and 1 m around the unit and non flammable objects must be observed The protective air suction grille must always be free of dirt and loose objects Never insert foreign matters into the unit The unit may not be exposed to direct water jets such as high pressure cleaning unit and so on All electrical cables of the unit must be p...

Page 5: ...ssociations the respective country construction ordinances and the burning appliance regulations basically apply For example for Germany Feuerungsanlagenverordnung FeuVo Furnace Installation Ordi nances of the individual states Unfallverhütungsvorschrift UVV Accident Prevention Regulation Heiz Flämm und Schmelzge räte für Bau und Montagear beiten Heating Burning and Melting Equipment for Construc ...

Page 6: ...mains plug of the device to a properly installed and secured mains socket 230 V 50 Hz CAUTION In case of defects that endan ger the operating safety of the unit the operation of the unit must be shut down immedi ately and the supervisor must be informed CAUTION All cable extensions may be used only when unrolled Paraffin formation at low out door temperatures Even in case of low temperatures free ...

Page 7: ...due to overheating 1 3 Notices regarding the safety cut off of the unit The unit fuel supply takes place in a single line system In this regard the fuel supply to the nozzle can be interrupted by blowing air during the initial start up or after the fuel tank has been completely emptied The automatic burner relay of the appliances shut down due to mal function in this case This shutdown due to malf...

Page 8: ...vicinity of the tank filler neck Note the direction of flow Use only clean EL heating oil or diesel Look for paraffin formation Allow only authorised expert personnel to clean the gauze filter in the fuel pump only by DZH 90 and exchange the nozzle Regularly check the safety appliances for correct function In case of a weakening heating capacity formation of smoke and or bad ignition inspect the u...

Page 9: ...ump and exchange if necessary 9 The fuel container is empty Fill the container with clean fuel 10 The oil filter is stopped up Clean or exchange oil firter 11 The nozzle is stopped up or has the wrong size Exchange the nozzle Pay attention to the right type and size 12 The electrode is incorrectly adjusted die isolation is defective Adjust or exchange it 13 The air inlet plate of the burner head i...

Page 10: ...10 REMKO DZH Exploded view DZH 20 2 We reserve the right to make changes in dimensions and design in the interest of technical advances 24 B A ...

Page 11: ...7131 41 Nozzle cradle 1107132 No Designation EDP No 42 Mounting plate 1111675 43 Nut 1107134 44 Photoelectric cell mount 1111676 45 Photoelectric cell 1108209 46 Ignition cable with plug 1107137 48 Ignition electrode 1107139 50 Auxiliary Relay 1107375 52 Ignition transformer 1107143 53 Support plate PE 1107188 55 Switch cabinet housing 1107189 56 Operating switch 1111677 58 Seal housing 1107190 59...

Page 12: ...12 REMKO DZH 27 B A Exploded view DZH 30 2 50 2 We reserve the right to make changes in dimensions and design in the interest of technical advances ...

Page 13: ...ine 1111674 1111674 No Designation DZH 30 2 DZH 50 2 EDP No EDP No 40 Nozzle 1107126 1111717 41 Nozzle cradle 1107132 1107132 42 Mounting plate 1111675 1111675 43 Nut 1107134 1107134 44 Photoelectric cell mount 1111676 1111676 45 Photoelectric cell 1108209 1108209 46 Ignition cable with plug 1107137 1107137 48 Ignition electrode 1107139 1107139 50 Auxiliary Relay 1107375 1107375 52 Ignition transf...

Page 14: ...8 61 56 54 62 63 52 50 51 81 71 56 1 4 15 16 16 15 17 2 5 A 48 3 7 58 16 8 10 6 9 15 11 20 21 22 29 29 27 24 29 28 39 38 37 30 31 32 36 43 44 25 45 40 35 45 Exploded view DZH 90 We reserve the right to make changes in dimensions and design in the interest of technical advances ...

Page 15: ...07148 43 Impact clamp 1107369 No Designation EDP no 44 Lower cover 1107370 45 Nut 1107371 48 Re cooling thermostat 1107182 50 Swivel disc 1103743 51 Nozzle 1107372 52 Nozzle mounting 1103745 53 Assembly plate 1107373 54 GE screw attachement 1103749 55 Ignition electrode 1103747 56 Ignition cable incl plug 1107137 58 Oil pressure pipe 1107125 61 Screw nut 1107134 62 Photoelectric cell 1108209 63 Ph...

Page 16: ...ng When disposing of the packaging material think of the environment Our equipment is carefully packed for transport and delivered in a stable cardboard transport package on a wooden pallet if necessary The packaging materials are environmentally friendly and can be reused With the reuse of packaging mate rial you make a valuable contribu tion to the reduction of waste and the preservation of raw ...

Page 17: ...erating switch C Condenser FZ Photoelecrtic cell HS Auxiliary relay M Motor MV Solenoid valve 1 2 3 4 5 6 7 8 9 10 11 12 PE L N 230 V 50 Hz BS RS MV FZ ZE ZT M C 2 3 RT NK STB A1 A2 14 11 HS 1 2 3 4 5 6 7 8 N 9 NK Re cooling thermostat RS Relay socket RT Thermostat plug socket STB Safety limiter ZE Ignition electrode ZT Ignition transformer ...

Page 18: ...Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Model Model No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Clean unit surface Clean unit interior Clean fan blade Clean fan housing Clean condenser Clean evaporator Fan function checked Intake grille with filter cleaned Check unit for damage Protective devices checked All fixing screws checked Electrical safety tes...

Page 19: ...er consumption W 200 290 430 690 Fuse protection on site A 10 10 10 10 Noise pressure level LpA 1m 2 dB A 74 77 78 79 Total length mm 800 1050 1090 1400 Total width mm 300 500 500 655 Total height mm 520 615 740 890 Weight kg 21 37 43 84 EDP no 116202 116302 116502 116900 Technical Data We reserve the right to make changes in dimensions and design in the interest of technical advances 1 The said p...

Page 20: ... and abroad but also unusually highly qualified sales experts REMKO sales representatives are more than just salespeople they must also be customer consultants in air conditioning and heating technology Customer care Our devices function precisely and reli ably If a malfunction appears however REMKO Customer Care is on the job Our extensive network of experienced dealers guarantees you constant sh...

Reviews: