19
Device type
DZH 20-2
DZH 30-2
DZH 50-2
DZH 90
Nominal heating capacity
kW
20
36
46
93
Air capacity
m
3
/h
350
605
1400
1800
Fuel
EL heating oil according to DIN 51603 or diesel fuel
Max. fuel consumption
l/h
2,01
3,62
4,62
9,38
Nozzle (Danfoss)
1)
USG
0,40/80°S
0,60/80°S
0,85/80°S
1,75/80°S
Pump pressure, approx.
1)
bar
11-12
12-13
14-15
14-14,5
Tank volume
Ltr.
17
40
62
105
Voltage supply
V/Ph
230/1~
230/1~
230/1~
230/1~
Frequency
Hz
50
50
50
50
Max. nominal current
A
1,0
1,3
1,8
3,7
Max. power consumption
W
200
290
430
690
Fuse protection (on site)
A
10
10
10
10
Noise pressure level L
pA
1m
2)
dB(A)
74
77
78
79
Total length
mm
800
1050
1090
1400
Total width
mm
300
500
500
655
Total height
mm
520
615
740
890
Weight
kg
21
37
43
84
EDP no:
116202
116302
116502
116900
Technical Data
We reserve the right to make changes in dimensions and design in the interest of technical advances.
1)
The said pump nozzle sizes and pressures resulting from adjust tests to the test stand.
The oil flow was calibrated.
Due to product-specific nozzle / pressure and tolerances as well as the oil temperature, the detail
to be regarded as guidelines only.
2)
Noise measurement according to DIN 45635 - 01 - Cl. 3