background image

5

Mounting Regulations

CAUTION

Avoid underpressure or over-
pressure in mounting rooms 
since these states always lead 
to combustion-technical  
problems.

Sequence of functions

After the unit has been switched on 
or in case heating is reqired (auto-
matic function with room thermos-
tat), the supply air fan also switched 
on.  
After the preliminary ventilation of 
the burner, the solenoid valve opens 
the fuel supply for the oil nozzle. 

The fuel, sprayed under high pres-
sure, is enriched with an amount of 
oxygen that has been adapted to the 
heating capacity and ignited using 
an electrical, high-voltage ignition 
spark.
As soon as a flame is burning wit-
hout a problem, the automatic bur-
ner relay assume the optical flame 
monitoring function.
After a short period of time, hot air 
is blown out.

The automatic burner relay perform 
all device functions fully automati-
cally and monitor them securely. 

In case of any irregularities or an 
instable or extinguished flame, the 
unit is deactivated by the automatic 
burner relay. 
The pilot lamp on the automatic 
burner relay lights red. 

A restart of the unit is only possible 
after a manual reset of the auto-
matic burner relay.

After the unit has been shut down 
using the operating switch or by 
the room thermostat, the supply air 
fan continues to run for a certain 
period of time to cool the combus-
tion chamber and then shuts down 
independently.

Concerning to each room tempe-
rature the thermostat operation 
repeats the descripted operation 
automatically.

When the unit is in use, the safety 
guidelines of the employers‘ liability 
insurance associations, the respective 
country construction ordinances, and 
the burning appliance regulations 
basically apply.
For example for Germany:

–   Feuerungsanlagenverordnung 

(FeuVo) (Furnace Installation Ordi-
nances) of the individual states

–   Unfallverhütungsvorschrift (UVV) 

(Accident Prevention Regulation) 
„Heiz-, Flämm- und Schmelzge-
räte für Bau- und Montagear-
beiten“ (Heating, Burning, and 
Melting Equipment for Construc-
tion and Mounting Work) (VBG 
43)

–   Unfallverhütungsvorschrift (UVV) 

„Verwendung von Flüssiggas“ 
(Use of Liquefied Gas) (VBG 21)

–   Arbeitsstättenrichtlinien ASR 5 

(Workstation Guidelines)

–   Arbeitsstättenverordnung (Work-

station Ordinance) §§ 5 and 14 

Outdoor mounting

   Due to the operation of the unit, 

no dangers or unreasonable    
nuisances may arise

   The unit operator must guaran-

tee that unauthorised persons 
cannot manipulate the unit or the 
energy supply

   To avoid damage due to incle-

ment weather, the unit must be 
mounted in a protected manner

Mounting in closed,  
well-ventilated rooms

   According to the type, the unit 

is designed without an exhaust 
connection and may be used in 
closed rooms only under certain 
circumstances

   To exclude an impermissible pol-

lution of the room air, a reliable 
exhaust of the combustion gases 
must always be guaranteed

   The supply of the fresh air 

required for proper combustion 
must be guaranteed. The fresh 
air supply should come through 
windows and doors or through 
sufficiently sized openings in the 
outer wall

   The unit may be used for room 

heating only with a room ther-
mostat (accessory)

The unit may be operated indoors 
only if:

-  A sufficient air volume for combu-

stion is supplied to the device.

-  The unit is well aerated and venti-

lated

-  The amount of pollutants in the 

breathing air that is hazardous to 
health may not reach an unreaso-
nable concentration

Summary of Contents for DZH 20

Page 1: ...Edition GB W08 REMKO DZH Oil Heaters Operation Technology Spare Parts ...

Page 2: ......

Page 3: ...8 Contents Subject to change errors and typographical errors excepted Safety Notices 4 Device Description 4 Mounting Regulations 5 Commissioning 6 Shutdown 7 Maintenance and Care 8 Trouble Shooting 9 Exploded view DZH 20 2 10 Spare Parts List DZH 20 2 11 Exploded view DZH 30 2 50 2 12 Spare Parts List DZH 30 2 50 2 13 Exploded view DZH 90 14 Spare Parts List DZH 90 15 Proper Use 16 Customer Servic...

Page 4: ... containing oil sulphur or salt A safety zone of 3 m around the exhaust and 1 m around the unit and non flammable objects must be observed The protective air suction grille must always be free of dirt and loose objects Never insert foreign matters into the unit The unit may not be exposed to direct water jets such as high pressure cleaning unit and so on All electrical cables of the unit must be p...

Page 5: ...ssociations the respective country construction ordinances and the burning appliance regulations basically apply For example for Germany Feuerungsanlagenverordnung FeuVo Furnace Installation Ordi nances of the individual states Unfallverhütungsvorschrift UVV Accident Prevention Regulation Heiz Flämm und Schmelzge räte für Bau und Montagear beiten Heating Burning and Melting Equipment for Construc ...

Page 6: ...mains plug of the device to a properly installed and secured mains socket 230 V 50 Hz CAUTION In case of defects that endan ger the operating safety of the unit the operation of the unit must be shut down immedi ately and the supervisor must be informed CAUTION All cable extensions may be used only when unrolled Paraffin formation at low out door temperatures Even in case of low temperatures free ...

Page 7: ...due to overheating 1 3 Notices regarding the safety cut off of the unit The unit fuel supply takes place in a single line system In this regard the fuel supply to the nozzle can be interrupted by blowing air during the initial start up or after the fuel tank has been completely emptied The automatic burner relay of the appliances shut down due to mal function in this case This shutdown due to malf...

Page 8: ...vicinity of the tank filler neck Note the direction of flow Use only clean EL heating oil or diesel Look for paraffin formation Allow only authorised expert personnel to clean the gauze filter in the fuel pump only by DZH 90 and exchange the nozzle Regularly check the safety appliances for correct function In case of a weakening heating capacity formation of smoke and or bad ignition inspect the u...

Page 9: ...ump and exchange if necessary 9 The fuel container is empty Fill the container with clean fuel 10 The oil filter is stopped up Clean or exchange oil firter 11 The nozzle is stopped up or has the wrong size Exchange the nozzle Pay attention to the right type and size 12 The electrode is incorrectly adjusted die isolation is defective Adjust or exchange it 13 The air inlet plate of the burner head i...

Page 10: ...10 REMKO DZH Exploded view DZH 20 2 We reserve the right to make changes in dimensions and design in the interest of technical advances 24 B A ...

Page 11: ...7131 41 Nozzle cradle 1107132 No Designation EDP No 42 Mounting plate 1111675 43 Nut 1107134 44 Photoelectric cell mount 1111676 45 Photoelectric cell 1108209 46 Ignition cable with plug 1107137 48 Ignition electrode 1107139 50 Auxiliary Relay 1107375 52 Ignition transformer 1107143 53 Support plate PE 1107188 55 Switch cabinet housing 1107189 56 Operating switch 1111677 58 Seal housing 1107190 59...

Page 12: ...12 REMKO DZH 27 B A Exploded view DZH 30 2 50 2 We reserve the right to make changes in dimensions and design in the interest of technical advances ...

Page 13: ...ine 1111674 1111674 No Designation DZH 30 2 DZH 50 2 EDP No EDP No 40 Nozzle 1107126 1111717 41 Nozzle cradle 1107132 1107132 42 Mounting plate 1111675 1111675 43 Nut 1107134 1107134 44 Photoelectric cell mount 1111676 1111676 45 Photoelectric cell 1108209 1108209 46 Ignition cable with plug 1107137 1107137 48 Ignition electrode 1107139 1107139 50 Auxiliary Relay 1107375 1107375 52 Ignition transf...

Page 14: ...8 61 56 54 62 63 52 50 51 81 71 56 1 4 15 16 16 15 17 2 5 A 48 3 7 58 16 8 10 6 9 15 11 20 21 22 29 29 27 24 29 28 39 38 37 30 31 32 36 43 44 25 45 40 35 45 Exploded view DZH 90 We reserve the right to make changes in dimensions and design in the interest of technical advances ...

Page 15: ...07148 43 Impact clamp 1107369 No Designation EDP no 44 Lower cover 1107370 45 Nut 1107371 48 Re cooling thermostat 1107182 50 Swivel disc 1103743 51 Nozzle 1107372 52 Nozzle mounting 1103745 53 Assembly plate 1107373 54 GE screw attachement 1103749 55 Ignition electrode 1103747 56 Ignition cable incl plug 1107137 58 Oil pressure pipe 1107125 61 Screw nut 1107134 62 Photoelectric cell 1108209 63 Ph...

Page 16: ...ng When disposing of the packaging material think of the environment Our equipment is carefully packed for transport and delivered in a stable cardboard transport package on a wooden pallet if necessary The packaging materials are environmentally friendly and can be reused With the reuse of packaging mate rial you make a valuable contribu tion to the reduction of waste and the preservation of raw ...

Page 17: ...erating switch C Condenser FZ Photoelecrtic cell HS Auxiliary relay M Motor MV Solenoid valve 1 2 3 4 5 6 7 8 9 10 11 12 PE L N 230 V 50 Hz BS RS MV FZ ZE ZT M C 2 3 RT NK STB A1 A2 14 11 HS 1 2 3 4 5 6 7 8 N 9 NK Re cooling thermostat RS Relay socket RT Thermostat plug socket STB Safety limiter ZE Ignition electrode ZT Ignition transformer ...

Page 18: ...Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Model Model No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Clean unit surface Clean unit interior Clean fan blade Clean fan housing Clean condenser Clean evaporator Fan function checked Intake grille with filter cleaned Check unit for damage Protective devices checked All fixing screws checked Electrical safety tes...

Page 19: ...er consumption W 200 290 430 690 Fuse protection on site A 10 10 10 10 Noise pressure level LpA 1m 2 dB A 74 77 78 79 Total length mm 800 1050 1090 1400 Total width mm 300 500 500 655 Total height mm 520 615 740 890 Weight kg 21 37 43 84 EDP no 116202 116302 116502 116900 Technical Data We reserve the right to make changes in dimensions and design in the interest of technical advances 1 The said p...

Page 20: ... and abroad but also unusually highly qualified sales experts REMKO sales representatives are more than just salespeople they must also be customer consultants in air conditioning and heating technology Customer care Our devices function precisely and reli ably If a malfunction appears however REMKO Customer Care is on the job Our extensive network of experienced dealers guarantees you constant sh...

Reviews: