Wiring Diagram

 

Technical Data 

Series

 

 

ETF 240

 

Operating range temperature 

°C 

6-32 

Operating range humidity 

% r. h. 

40-100 

Dehumidification capacity max. 

l/day 

26 

at 30 °C / 80 % r.h 

l/day 

24,4 

Air capacity, max. 

m³/h 

190 

Refrigerant 

—— 

R 134a 

Refrigerant amount 

240 

Electrical connection 

1 ~ 230 

Frequency 

Hz 

50 

Rated current max. 

3,4 

Power consumption max. 

kW 

0,62 

Fuse protection (supplied) 

10 

Sound pressure level L

pA 

1m

 

1) 

 

dB(A) 

43 

Depth 

mm 

314 

Width 

mm 

390 

Height 

mm 

612 

Weight 

kg 

21 

 

 

 

 

1) Noise measurement DIN 45635 - 01 - KL 3

 

Proper Use 

The units have been designed and equipped exclusively 
for dehumidification purposes. 

The  manufacturer  assumes  no  liability  for  damage  re-
sulting  from  non-compliance  with  manufacturer  specifi-
cations  and  legal  requirements,  or  if  modifications  are 
made to the units. 

 

Operation/handling which does not comply with 
these instructions is prohibited!  
In cases of non-compliance, we assume no liability 
and the guarantee becomes null and void.

 

Customer Service and Guaran-
tee

 

 

For the guarantee to be valid, the purchaser or his custom-
er  must  completely  fill  out  the  "guarantee  certificate"  en-
closed with all units and send it back to REMKO GmbH & 
Co. KG

The units are repeatedly tested at the production site to 
ensure  that  they  are  working  properly.  If  a  malfunction 
occurs  that  cannot  be  eliminated  by  the  operating  per-

M

M

Summary of Contents for ETF 240

Page 1: ...REMKO ETF 240 Portable Air Dehumidifier Edition GB S10 Operation Technology REMKO powerful like a bear...

Page 2: ......

Page 3: ...ions Portable air dehumidifier REMKO ETF 240 Contents Page Air Dehumidification 4 Safety Instructions 6 Description of the Unit 6 Setup 7 Control Panel 7 Initial Operation 8 Shutting Down the Unit 9 C...

Page 4: ...percentage of water is indicated in g per kg of dry air absolute water content 1 m of air weighs approx 1 2 kg at 20 C Depending on the temperature each kg of air can only absorb a defined quantity o...

Page 5: ...ergy is released when gas is lique fied and this energy is called condensation heat The energy produced from evaporation and condensa tion heat is identical For water this is 2250 kJ kg 4 18 kJ 1kcal...

Page 6: ...ume no liability and the guarantee becomes null and void Work on the cooling system and the electrical sys tem may only be performed by authorised person nel Description of the Unit The unit has been...

Page 7: ...The unit must be securely placed in an upright posi tion so that condensation can drain freely into the condensation tank If possible place the unit in the middle of the room to ensure optimum air cir...

Page 8: ...rds You can adjust the direction of the air any way you want Hygrostat setting for the recommended humidity in residences Approx 50 Hygrostat setting for the recommended humidity in archives Approx 40...

Page 9: ...wing out of the condensation tank 1 Using a suitable tool break the cover F of the connection adapter from the unit wall Only necessary for the initial connection 2 Connect a drainage hose that is suf...

Page 10: ...erly in accordance with general regula tions and local requirements Import information on recycling Work on the cooling system and the electrical sys tem may only be performed by authorised person nel...

Page 11: ...xclusively for dehumidification purposes The manufacturer assumes no liability for damage re sulting from non compliance with manufacturer specifi cations and legal requirements or if modifications ar...

Page 12: ...6 5 8 9 10 11 17 19 21 22 25 28 30 35 33 31 39 38 40 41 42 44 46 49 51 47 48 20 29 36 32 Exploded View We reserve the right to make changes to dimensions and design in the interest of technical progr...

Page 13: ...r 1103642 29 Circuit board control lights 1103674 30 Cover control lights 1103663 31 Hygrostat 1103664 32 Control panel 1103665 33 Rotating knob 1103666 35 PCB with control 1103675 36 Condensor 110366...

Page 14: ...13 14 15 16 17 18 19 20 Model Model No The unit must be maintained according to legal regulations by authorised personnel only Remarks 1 Date 2 Date 3 Date 4 Date 5 Date Signature Signature Signature...

Page 15: ......

Page 16: ...REMKO GmbH Co KG Klima und W rmetechnik 32791 Lage Im Seelenkamp 12 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606 260 E mail info remko de Internet www remko de...

Reviews: