Operating Instructions 

Read these instructions carefully before setting up/operating the unit! 

 

 

Our guarantee becomes null and void if the unit is used, set up or maintained improperly, or if 

modifications are made to the supplied unit without our prior consent. 

Subject to alterations. 

Portable air dehumidifier  

REMKO ETF 240 

Contents

 

Page  

 
Air Dehumidification 

Safety Instructions  

Description of the Unit 

Setup 

Control Panel 

Initial Operation 

Shutting Down the Unit 

Cleaning the Filter 

Contents 

Page  

 
Maintenance and Service 

10 

Troubleshooting 

10 

Technical Data 

11 

Wiring Diagram 

11 

Customer Service and Guarantee  11 

Exploded View 

12 

Spare Part List 

13

 

Maintenance and Service Log 

14 

Always keep these operating instructions near or on the unit.

 

 

 

Summary of Contents for ETF 240

Page 1: ...REMKO ETF 240 Portable Air Dehumidifier Edition GB S10 Operation Technology REMKO powerful like a bear...

Page 2: ......

Page 3: ...ions Portable air dehumidifier REMKO ETF 240 Contents Page Air Dehumidification 4 Safety Instructions 6 Description of the Unit 6 Setup 7 Control Panel 7 Initial Operation 8 Shutting Down the Unit 9 C...

Page 4: ...percentage of water is indicated in g per kg of dry air absolute water content 1 m of air weighs approx 1 2 kg at 20 C Depending on the temperature each kg of air can only absorb a defined quantity o...

Page 5: ...ergy is released when gas is lique fied and this energy is called condensation heat The energy produced from evaporation and condensa tion heat is identical For water this is 2250 kJ kg 4 18 kJ 1kcal...

Page 6: ...ume no liability and the guarantee becomes null and void Work on the cooling system and the electrical sys tem may only be performed by authorised person nel Description of the Unit The unit has been...

Page 7: ...The unit must be securely placed in an upright posi tion so that condensation can drain freely into the condensation tank If possible place the unit in the middle of the room to ensure optimum air cir...

Page 8: ...rds You can adjust the direction of the air any way you want Hygrostat setting for the recommended humidity in residences Approx 50 Hygrostat setting for the recommended humidity in archives Approx 40...

Page 9: ...wing out of the condensation tank 1 Using a suitable tool break the cover F of the connection adapter from the unit wall Only necessary for the initial connection 2 Connect a drainage hose that is suf...

Page 10: ...erly in accordance with general regula tions and local requirements Import information on recycling Work on the cooling system and the electrical sys tem may only be performed by authorised person nel...

Page 11: ...xclusively for dehumidification purposes The manufacturer assumes no liability for damage re sulting from non compliance with manufacturer specifi cations and legal requirements or if modifications ar...

Page 12: ...6 5 8 9 10 11 17 19 21 22 25 28 30 35 33 31 39 38 40 41 42 44 46 49 51 47 48 20 29 36 32 Exploded View We reserve the right to make changes to dimensions and design in the interest of technical progr...

Page 13: ...r 1103642 29 Circuit board control lights 1103674 30 Cover control lights 1103663 31 Hygrostat 1103664 32 Control panel 1103665 33 Rotating knob 1103666 35 PCB with control 1103675 36 Condensor 110366...

Page 14: ...13 14 15 16 17 18 19 20 Model Model No The unit must be maintained according to legal regulations by authorised personnel only Remarks 1 Date 2 Date 3 Date 4 Date 5 Date Signature Signature Signature...

Page 15: ......

Page 16: ...REMKO GmbH Co KG Klima und W rmetechnik 32791 Lage Im Seelenkamp 12 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606 260 E mail info remko de Internet www remko de...