The  unit’s  fully  automatic  control  system,  continuously 
adjustable  hygrostat,  condensation  collection  tank  with 
integrated overflow protection and hose connections for 
the  direct  disposal  of  condensation  guarantee  trouble-
free long-term use.  

The unit meet the basic safety and health requirements 
found in the relevant EU regulations. It is safe and easy 
to operate. 

Safety Instructions

 

 
Extensive  tests  have  been  conducted  on  the  material, 
functionality  and  quality  of  this  unit  before  it  was 
shipped. 

Hazards  may  nevertheless  arise  if  the  unit  is  used  by 
persons not familiar with its operation or if the unit is not 
used for its intended purpose! 

Please  also  make  sure  to  follow  these  safety  instruc-
tions. 

 

The  unit  may  not  be  set  up  or  operated  in  rooms 
susceptible to explosions. 

 

The unit may  not  be set  up and  operated  in rooms 
whose  atmosphere  is  contaminated  by  oil,  sulfur, 
chlorine or salt. 

 

The unit must be securely placed in an upright posi-
tion. 

 

The  unit  may  not  be  exposed  to  a  direct  stream  of 
water. 

 

The  air  intake  and  outlet  openings  may  never  be 
blocked. 

 

The air  intake side must always  be free of dirt and 
loose objects. 

 

Never insert foreign objects into the unit. 

 

The  unit  may  not  be  covered  or  transported  during 
operation. 

 

The  electrical  cables  outside  the  unit  must  be  pro-
tected from being damaged (e.g. by animals). 

 

Make  sure  that  extension  cables  are  suitable  in 
terms of capacity, length and intended use. 

 

The unit may only be transported in an upright posi-
tion,  the  condensation  tank  must  be  emptied  each 
time before the unit is moved. 

 

The  unit  may  not  be  operated  for  a  different  pur-
pose or other than as described in this manual

.

  

In cases of non-compliance, we assume no liability 
and the guarantee becomes null and void.

 

 

Work on the cooling system and the electrical sys-
tem may only be performed by authorised person-
nel!

 

Description of the Unit 

 
The  unit  has  been  designed  for  automatic,  universal, 
smooth  air  dehumidification.  Its  compact  dimensions 
make it easy to transport and set up. 

The  unit  works  on  the  principle  of  condensation.  It  is 
equipped with a closed-loop cooling system, a quiet fan 
requiring little maintenance and a power cord with plug. 

The unit has control lights on the control panel to check 

Unit setup locations 

The  unit  is  used  in  rooms  where  dry  air  is  a  priority  to 
avoid consequential financial losses (e.g. as a result of 
a buildup of mildew).

 

The unit is primarily used to dry and dehumidify: 

 

Living rooms, bedrooms, showers or basements. 

 

Kitchens, weekend houses, caravans. 

And to keep the following dry on an permanent basis: 

 

Storage areas, archives, laboratories. 

 

Bathing, washing, changing rooms, etc. 

Function

 

The unit works on the principle of condensation. 

The 

fan 

sucks the moist ambient air into the back of the 

unit  via the  air filter, the evaporator and the condenser 
located behind the evaporator. 

Heat is extracted from the ambient air at the cold 

evap-

orator

. The ambient air is cooled until it falls below the 

dew  point  and  the  water  vapour  contained  in  the  air 
turns into condensation or frost on the evaporator fins. 

 

 

 

 

Diagram of how the unit functions 

Moist air 

Compensation 

tray 

Condensation- 

tank 

Fan 

Condenser 

Evaporator 

Dehumidified air 

Compressor 

The  dehumidified, cooled  air  is reheated  in  the 

conden-

ser 

(heat-exchanger)  and  then  released  at  a  tempera-

ture  of  approximately  5  degrees  above  room  tempera-
ture. 

This air, which is now drier, is mixed again with the am-
bient air. The humidity of the air is gradually reduced to 
the desired relative humidity through the continuous cir-
culation of ambient air by the unit. 

Summary of Contents for ETF 240

Page 1: ...REMKO ETF 240 Portable Air Dehumidifier Edition GB S10 Operation Technology REMKO powerful like a bear...

Page 2: ......

Page 3: ...ions Portable air dehumidifier REMKO ETF 240 Contents Page Air Dehumidification 4 Safety Instructions 6 Description of the Unit 6 Setup 7 Control Panel 7 Initial Operation 8 Shutting Down the Unit 9 C...

Page 4: ...percentage of water is indicated in g per kg of dry air absolute water content 1 m of air weighs approx 1 2 kg at 20 C Depending on the temperature each kg of air can only absorb a defined quantity o...

Page 5: ...ergy is released when gas is lique fied and this energy is called condensation heat The energy produced from evaporation and condensa tion heat is identical For water this is 2250 kJ kg 4 18 kJ 1kcal...

Page 6: ...ume no liability and the guarantee becomes null and void Work on the cooling system and the electrical sys tem may only be performed by authorised person nel Description of the Unit The unit has been...

Page 7: ...The unit must be securely placed in an upright posi tion so that condensation can drain freely into the condensation tank If possible place the unit in the middle of the room to ensure optimum air cir...

Page 8: ...rds You can adjust the direction of the air any way you want Hygrostat setting for the recommended humidity in residences Approx 50 Hygrostat setting for the recommended humidity in archives Approx 40...

Page 9: ...wing out of the condensation tank 1 Using a suitable tool break the cover F of the connection adapter from the unit wall Only necessary for the initial connection 2 Connect a drainage hose that is suf...

Page 10: ...erly in accordance with general regula tions and local requirements Import information on recycling Work on the cooling system and the electrical sys tem may only be performed by authorised person nel...

Page 11: ...xclusively for dehumidification purposes The manufacturer assumes no liability for damage re sulting from non compliance with manufacturer specifi cations and legal requirements or if modifications ar...

Page 12: ...6 5 8 9 10 11 17 19 21 22 25 28 30 35 33 31 39 38 40 41 42 44 46 49 51 47 48 20 29 36 32 Exploded View We reserve the right to make changes to dimensions and design in the interest of technical progr...

Page 13: ...r 1103642 29 Circuit board control lights 1103674 30 Cover control lights 1103663 31 Hygrostat 1103664 32 Control panel 1103665 33 Rotating knob 1103666 35 PCB with control 1103675 36 Condensor 110366...

Page 14: ...13 14 15 16 17 18 19 20 Model Model No The unit must be maintained according to legal regulations by authorised personnel only Remarks 1 Date 2 Date 3 Date 4 Date 5 Date Signature Signature Signature...

Page 15: ......

Page 16: ...REMKO GmbH Co KG Klima und W rmetechnik 32791 Lage Im Seelenkamp 12 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606 260 E mail info remko de Internet www remko de...

Reviews: