background image

11

Turn the hygrostat’s 
rotary knob 
anticlockwise 
into the 
“OFF” position. 

If the units are 
inactive for longer 
periods, disconnect 
them from the mains 
power supply.

Empty the condensate container 
completely and dry with a clean 
cloth.  

Beware of dripping condensate!

 

The units must be cleaned and 
dried completely before storing.

When storing the unit, cover with 
a plastic sheet/foil if necessary 
and store in an upright position in 
a sheltered and dry location.

The units are only permitted to be 
stored upright in a suitable storage 
location that is protected against 
dust and direct sunlight. 

Continuous operation with 
external condensate outlet

 

The units are equipped with 
a special connection nozzle on the 
left side. 
A standard 1/2” water hose can 
be connected to this. 

1.  To do this, use a suitable tool 

to break the cover [F] out of the 
side wall.  

Only

 

required for the first 

connection!

 

2.  Connect a sufficiently long 

and suitable drain hose to the 
connection nozzle that is now 
exposed. 

In unattended permanent 
operating mode, the condensate 
should preferably be drained into 
a lower-level drain.  
If using an external collection 
container (pan, bucket, etc.), 
the unit must be placed 
at a correct height.

Shutdown

F

Emptying the condensate 
container

The integrated condensate 
container must be emptied from 
time to time. 

Dehumidification mode is switched 
off if the condensate container is 
full. 
The “Container full” indicator light 
indicates that the unit has switched 
off. 

1.  Pull the full container forwards 

and out carefully. 

2.  Pour the water into a drain.

3.  Re-insert the emptied container 

carefully into the unit. 

The “Container full” indicator light 
extinguishes and the unit 
continues to run automatically. 

NOTE

The unit can only be started 
once the condensate container 
has been inserted correctly.

NOTE

After being emptied, the 
condensate container incl. 
float must be checked for 
damage, contamination etc. 

There is no unit overflow 
protection in this variant.

 

!

   CAUTION

Ensure that the drainage hose 
is placed at an incline to the 
drain to allow the condensate 
to drain without hindrance! 

 

!

   CAUTION

Summary of Contents for ETF 320

Page 1: ...Edition GB I03 REMKO ETF 320 Mobile dehumidifiers Operation Technology Spare parts...

Page 2: ......

Page 3: ...or on the unit itself Subject to modifications no liability accepted for errors or misprints Air dehumidification 4 Safety notes 6 Unit description 7 Set up 8 Commissioning 9 Shutdown 11 Unit transpo...

Page 4: ...r vapour released from parts of a building or materials is absorbed by the surrounding air As a result the moisture content increases which ultimately gives rise to corrosion mould rot peeling of pain...

Page 5: ...emperature to fall below it Building materials and structures are capable of absorbing considerable volumes of water such as brick 90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m The d...

Page 6: ...t on the output of the unit but is determined to a greater extent by the speed at which the material or building section loses its moisture The units have been subjected to extensive material function...

Page 7: ...xtinguishes again when the empty condensate container is re inserted The units then restart after a switch on delay of around 3 minutes In unattended continuous operation with an external condensate c...

Page 8: ...if the unit is set up approx 1 m above the ground The room being dried or dehumidified must be closed to the surrounding atmosphere Avoid having opened windows and doors etc and avoid frequent entry...

Page 9: ...a waiting time of 3 minutes has elapsed Restart protection NOTE The devices can be switched ON and OFF via an external time accessory if required Before commissioning the unit or if local requirements...

Page 10: ...rly fast and effective and guarantees high dehumidification performance Dehumidification mode is only paused for a short time during the defrost phase The Defrost mode indicator light indicates that t...

Page 11: ...the connection nozzle that is now exposed In unattended permanent operating mode the condensate should preferably be drained into a lower level drain If using an external collection container pan buck...

Page 12: ...utlet grille for contamination on a regular basis Clean or replace if required Care and maintenance NOTE Regular care and maintenance is fundamental to a long service life and fault free operation of...

Page 13: ...ax 40 C soap solution Finally always rinse the filter carefully with clear water and allow to dry 7 Also check the intake grill for contamination and clean if necessary 8 Before refitting grill and fi...

Page 14: ...tutory or locally applicable regulations The unit is loud or condensate runs out Check whether the unit is on a stable and even base Check whether the unit is standing upright and stably Have the cond...

Page 15: ...are environmentally friendly and can be recycled By recycling packaging materials you make a valuable contribution to the reduction of waste and conservation of raw materials Therefore only dispose o...

Page 16: ...it We reserve the right to modify the dimensions and design as part of the ongoing technical development process 1 3 6 5 10 29 27 34 24 19 16 15 40 41 43 17 18 26 28 39 9 25 7 35 36 32 23 30 33 21 31...

Page 17: ...1103673 20 Fan motor 1103661 21 Fan housing 1111133 22 Fan wheel 1103636 23 Protection grid 1103637 24 Condenser fan motor 1103668 25 Distribution block 1111134 26 Mains cable with plug 1103660 27 Boa...

Page 18: ...Fan function checked Air inlet grid with filter cleaned Unit checked for damage Safety devices checked All fastening screws checked Electrical safety check Test run 1 Date Signature 2 Date Signature 3...

Page 19: ...15 2 At 15 C 60 RH l day 8 4 Max airflow volume m3 h 190 Condensate container capacity Litres 5 5 4 5 Refrigerant 1 R 410A Refrigerant quantity g 180 Power supply V 230 1 Frequency Hz 50 Max rated cur...

Page 20: ...dvisers to our customers in air conditioning and heating technology Customer service Our units operate precisely and reliably However in the event of a malfunction REMKO customer service is quickly on...

Reviews: