The unit must always be switched
off with the on/off switch.
■
Do not place anything on the
device in particular heavy or hot
objects.
■
Repairs may only be carried out
by authorised and certified spe-
cialist personnel.
■
This unit must be disposed of
professionally in accordance with
environmental protection.
■
The safety notes in regards to the
room sizes and the flammability
of the refrigerant must not be
removed from the machine.
■
The units may only be operated
in well ventilated areas.
■
The unit can be used by children
8 years and up and by persons
without physical, mental or other
health limitations if this knowl-
edge has been obtained via the
necessary safety notes..
■
Children must never play with the
unit.
■
Cleaning the units must not be
carried out by children without
parental/guardian supervision.
The following notes must be
observed in full:
■
The units must not be operated
at an ambient temperature
below 3 °C.
■
The units may not be set
up or operated in explosive
environments.
■
The units must not be installed
or operated in atmospheres
containing oil, sulphur, chlorine,
salt or dust.
■
Never insert foreign objects into
the units.
■
The units may not be exposed to
direct jets of water.
■
An unobstructed air inlet and air
outlet must be guaranteed at all
times.
■
The air-inlet grille must always
be kept free of dirt and loose
objects.
■
The units must not be covered
during operation.
■
The units must be installed
upright and in a stable position.
■
The units must not be
transported while they are
running.
■
All electrical cables on the
outside of the units must be
protected against damage (e.g.
by animals etc.).
■
Before each change of location,
the condensate containers must
be emptied.
■
Appropriate hazard prevention
measures must be taken to
prevent risks to people when
performing installation, repair,
maintenance or cleaning work on
the units.
■
The units and components
should not be exposed to any
mechanical load, extreme levels
of humidity or direct exposure to
sunlight.
Caution, risk of fire
Additional safety notes when
handling refrigerant R290
■
The refrigerant R290 fulfils the
requirements of the European
F-Gas regulation.
■
The units contain 0.200 kg (ETF
500 Eco) or 0,250 kg
(ETF 600
Eco) of refrigerant R290 depend-
ing on the unit type.
■
The maximum permitted amount
of refrigerant R290 is 0.3 kg.
■
The units must not be burned,
drilled or pierced.
■
Only use cleaning agents which
have been approved by the
manufacturer for cleaning.
■
The unit must never be operated
in rooms with naked flames (e.g.
gas heaters, open fireplaces, etc.).
■
Refrigerant circuit components
must not be deformed.