7

RE

SET

Technical data

Series

RTV 15

RTV 30 

Design

Turbo fan

Turbo fan

Ventilation capacity, 3-stage

m

3

/h

1200/1000/580

2400/2300/2150

Max. pressure

Pa

200

620

Electrical connection

V/Hz

230/1~/50

230/1~/50

Max. power consumption

Watt

220

680

Fuse protection (on site)

A

10

10 / 16

Max. current consumption

A

1.1

3.1

Type of protection 

IP

44

44

Sound pressure level

dB (A)

58

69

Max. conveyor temperature

°C

40

40

Hose connection Ø (optional multi-connection adapter)

mm

100

Max. tube length (optional multi-connection adapter)

m

3 x 10

Dimensions - height/width/depth

mm

340/290/310

430/400/470

EDP No:

1610700

1610730 / 1610731

Weight 

kg

5

14

No.

Designation

RTV 15 / Ref. no. RTV 30 / Ref. no.

1

Protection grid for air inlet

1113050

1113061

2

Electric motor

1113051

1113062

3

Fan housing

1113052

1113063

4

Fan cylinder

1113053

1113064

5

Control panel

1113054

1113065

5a

Control panel for additional socket

— —

1113066

6

3-speed operating switch, complete

1113055

1113067

7

Condenser

— —

1113068

9

Operating hours counter / additional 230V socket not shown

— —

1113048 / 1113069

10

Protection grid for air output

1113056

1113070

11

Protection grid for air inlet 

(for RTV 15 with motor support)

1113057

1113071

12

Protective switch with reset button

1113058

1113072

13

Cover plate

1113059

— —

Not 

shown

Mains cable with plug

1113060

1113073

Spare parts list

9

10

12

10

13

11

12

11

7

6

6

1

1

4

4

5

6

5

2

2

3

3

We reserve the right to make changes to dimensions and the design in the interest of technical advances.

RTV 15

RTV 30

Summary of Contents for RTV 15

Page 1: ...Edition GB G12 REMKO RTV 15 30 High performance fans for construction and renovations Operation Technology Spare parts ...

Page 2: ...2 ...

Page 3: ...ng 6 Technical data 7 Spare parts list 7 These operating instructions must be read carefully before commissioning using the unit These instructions are part of the unit and must always be kept in the direct vicinity of the site of installation or on the unit This operating manual is a translation of the German original We reserve the right to make changes no liability for errors and misprints ...

Page 4: ...d to a direct jet of water Never allow water to enter the unit All electric cables of the units must be protected against dam age e g by animals etc The unit musst not be transport ed during operation People who use the unit must be familiar with the risks arising with the use of conveying fans Use hearing protection when in the vicinity of the unit for a longer period of time The combination of a...

Page 5: ...be cleaned only dry or with a moist cloth and a small amount of soap solution if necessary Under no circumstances use high pressure cleaners or steam jet equipment Do not use caustic cleaning agents or cleaning agents con taining solvents Avoid causing damage when using compressed air Set the operating switch to the 0 position Read the operating hours coun ter For extended periods of non use Disco...

Page 6: ...serve the manufacturer s instructions or applicable statu tory requirements or unauthorised changes to the units Intended use Disposal of packaging When disposing of the packag ing material please think of the environment Our units are carefully packed for transport and delivered in sturdy cardboard packaging on a wooden pallet if necessary The packaging materials are environmentally friendly and ...

Page 7: ... RTV 15 Ref no RTV 30 Ref no 1 Protection grid for air inlet 1113050 1113061 2 Electric motor 1113051 1113062 3 Fan housing 1113052 1113063 4 Fan cylinder 1113053 1113064 5 Control panel 1113054 1113065 5a Control panel for additional socket 1113066 6 3 speed operating switch complete 1113055 1113067 7 Condenser 1113068 9 Operating hours counter additional 230V socket not shown 1113048 1113069 10 ...

Page 8: ...ustomers with consulting serv ices in regard to air conditioning and heating technology Customer service Our units operate precisely and reliably If a fault should occur REMKO Customer Service is there to help you Our extensive network of experienced special ised dealers guarantees you a fast and reliable service REMKO INTERNATIONAL and somewhere near you Take advantage of our experience and advic...

Reviews: