Safety notes
The units have been subjected to
extensive material, functional and
quality inspections prior to delivery.
However, dangers can result
from the units if they are used
improperly or not as intended by
untrained personnel.
Please observe the following notes:
■
The units may only be operated
by persons that have been
instructed in the operation of the
equipment
■
The units must be installed and
operated in such a way that
personnel are not endangered
by radiant heat and no fires may
occur
■
The units must only be operated
in areas where the units can
be supplied with an adequate
amount of air for combustion
If this cannot be ensured,
a separate burner fresh air intake
from outside must be installed.
■
The units may only be installed
on a non-combustible surface
■
The units may only be mounted
on stable structures or ceilings
made of non-flammable
construction materials and with
sufficient bearing capacity
■
The fastening must take place
with bearing anchors, which are
to be fastened to the unit
■
The units may not be installed
or operated in potentially
flammable or explosive
environments
■
The units must be installed away
from traffic zones - also by
crane, for example.
■
A safety zone with a clearance of
1 m must be ensured
■
The protective grid of the intake
must always be kept free of dirt
and loose objects
■
Never insert foreign objects into
the unit
■
The units must not be exposed
to direct jets of water e.g.
pressure washers, etc.
■
Never allow water to enter the
inside of the units
■
All electrical cables for the
units must be protected against
damage (including damage
caused by animals)
Always observe the respective local building code and fire prevention guidelines
as well as the guidelines of the accident prevention and insurance associations
when using the units.
CAUTION
If the unit is delivered from the
factory without a forced-air
burner and a third-party burn-
er brand is used, it is essential
to ensure that it is suitable for
the respective type and brand
of fan-assisted heater.
NOTE
Only type-approved forced-air
oil burners in WLE design per
DIN EN 298 and DIN EN 267
(oil) as well as DIN EN 676
(gas) should be used.
■
Portable fuel containers must
only be set up and used in
observance of the technical rules
for combustible liquids "TRbF
20".
■
This unit can be used by
children above the age of
8, as well as by people with
impaired physical, sensory or
mental capabilities or a lack
of experience and knowledge
if they are supervised or have
received instruction in the safe
operation of the unit, and if
they understand the associated
potential hazards. Children
must never play with the unit.
Cleaning and user maintenance
must not be carried out by
unsupervised children.
!