background image

15 

No.

 

Description

 

Ref.-No. 

 

Blow-out cone cpl.  

289172 

Blow-out grille 

1108154 

Safety temperature limiter (STB) 

1101197 

Temperature monitor  

(TW) 

1103146 

Combustion chamber, cpl. 

1103158 

Middle plate 

1103151 

Operating switch 

1101188 

Control lamp, green (in operation) 

1105514 

Control lamp, red (burner malfunction) 

1105363 

10 

Lining plate

, control panel 

1103147 

11 

Lining plate

, front / bottom 

1103145 

12 

Lining plate

, front 

1103143 

13 

Insulation, front 

1103142 

14 

Unit frame

, cpl. 

1103148 

15 

Air suction grille 

289109 

16 

Fan, cpl. 

1108606 

17 

Seal for inspection cover 

1103156 

18 

Inspection cover, (with waste gas connection) 

1103155 

19 

Waste gas suppressor (set = 6 piece) 

1103157 

20 

Fan control thermostat (TR) 

1101683 

21 

Lining plate

, rear 

1102976 

22 

Rosette for waste gas connection 

1103285 

23 

Lining plate

, rear 

1103153 

24 

Insulation, rear 

1103152 

25 

Lining plate

, top / bottom 

1103140 

26 

Lining plate

, top / bottom 

1102977 

27 

Insulation, top / bottom 

1103141 

 

 

 

not shown 

Oil nozzle (Steinen) 0,45 / 60°S 

 

Spare Part List 

We reserve the right to make modifications in dimensions and construction in the interests of technical progress. 

When ordering spare parts please indicate ref. no. and machine no. (see model plate)!

 

Summary of Contents for WKL 20 INOX

Page 1: ...REMKO powerful like a bear REMKO WKL 20 INOX Oil compact heating system Edition GB P11 Operation Technology Spare Parts...

Page 2: ......

Page 3: ...Oil Burner Assembly 16 Initial Operation 16 Service and Guarantee 17 Maintenance Log 18 Stationary Warm Air Heating System REMKO WKL 20 INOX Read these instructions carefully before setting up operati...

Page 4: ...connect the units to an exhaust system approved by the state building authorities The units are equipped with a 1 speed radial fan with drive motor that runs quietly and requires little mainte nance a...

Page 5: ...bend the capillary tubes near to solder points When installing the capillary tubes be careful not to damage or bend them too sharply The sensors may only be mounted in the mounting brackets supplied b...

Page 6: ...tup room but not close to hazardous areas Air Supply for Combustion An adequate supply of air for combustion must be en sured by meeting the relevant building requirements Excerpts from the German fir...

Page 7: ...e units the regional provisions and regulations must be observed The units may only be operated with accessories that have either been approved by the manufacturer or sup plied with the units Proceed...

Page 8: ...f the burner sup plied by the manufacturer If burners from other manufacturers are used they must be checked for compatibility with the unit Fan Motor Connection The units are completely wired at the...

Page 9: ...If the unit is not set to its rated heat load or it is too large for the necessary heat requirements the burner only runs in cyclical operation Because the required operating temperature is not reache...

Page 10: ...er Combustion residue in the com bustion chamber and in the heat exchanger must be removed Parts that wear out e g flue gas brakes oil nozzles oil filter inserts seals etc must be checked cleaned and...

Page 11: ...and capillary pipes of the safety temperature limiter STB and the temperature moni tor TW for damage and ensure that the sensor has been properly positioned Check whether the red control light burner...

Page 12: ...max unit without burner kW 0 17 Power consumption max for manufacturer supplied burner kW 0 28 Sound pressure level LpA 1m without burner dB A 58 Waste gas connection mm 130 Weight Unit without burne...

Page 13: ...ture limiter TH Optional Room thermostat or day night regulator TR Fan control thermostat TW Temperature monitor WS Wieland plug We reserve the right to make modifications in dimensions and constructi...

Page 14: ...Exploded View 4 1 2 5 3 13 8 9 12 11 7 3 4 10 16 15 20 18 19 17 21 22 23 26 25 27 14 24 6 We reserve the right to make modifications in dimensions and construction in the interests of technical progre...

Page 15: ...ction grille 289109 16 Fan cpl 1108606 17 Seal for inspection cover 1103156 18 Inspection cover with waste gas connection 1103155 19 Waste gas suppressor set 6 piece 1103157 20 Fan control thermostat...

Page 16: ...manually but not so that they are completely tight initially The sliding flange still has to be tightened 4 Push the flame pipe into the burner chamber until it clicks into place 5 Connect the flame p...

Page 17: ...the guarantee to be valid the customer must com pletely fill out the guarantee certificate enclosed with all heating units and send it back to REMKO GmbH Co KG in a timely manner after purchasing of t...

Page 18: ...damage Maintenance burner Test run Model Model No Burner Burner No Maintenance work may only be performed by authorised personnel settings must comply with legal specifications A corresponding test lo...

Page 19: ......

Page 20: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606 260 E Mail info remko de Internet www remko de...

Reviews: