G3-8 MA FM 5207
–
R03
7
Airplane and Systems Description
Systeme 7 - 58
Through the fuel shut-off valve and the firewall, the fuel is routed
towards the fuel divider. This unit provides ports for measuring fuel
pressure and fuel flow and feeds the carburetors.
NOTE
With the fuel shut-off valve closed no fuel is fed to the
engine and the engine will fail due to fuel starvation. It is
recommended to always keep the fuel valve open. The
fuel shut-off valve is a safety item to shut off the fuel in
emergency situations and need not be closed for parking
or hangaring.
NOTE
In case of a low fuel pressure warning cross check with
fuel flow. As long as fuel flow gives reasonable indication,
the reason for the warning is most probably found in the
fuel pressure sensor or its sensing hose. Vice versa the
same applies for the fuel flow sensor.
NOTE
It is recommended to keep the electric fuel pump
switched on during the entire flight.
NOTE
Service with permitted fuel grade only and regularly drain
the aircraft fuel system
For further information see maintenance manual section 12.
Summary of Contents for REMOS GX nXES
Page 12: ...G3 8 MA FM 5201 R01 1 General Information General Information 1 8 intentionally left blank...
Page 92: ...G3 8 MA FM 5205 R01 5 Performance Performance 5 14 intentionally left blank...
Page 163: ...POH Supplement Flight Training...
Page 177: ...POH Supplement Glider Towing...
Page 197: ...POH Supplement Banner Towing...
Page 213: ...POH Supplement Continued Airworthiness...
Page 229: ...POH Supplement Abbreviated checklists...
Page 235: ...G3 8 MA FM 1213 R01 Imprint Supplement Abbreviated Checklists 13 6 intentionally left blank...