background image

 

 

13 

 

IR

 

Port

 

Number

 

IR

 

Output

 

Power

 

Mode

 

Default

 

value

 

1

 

Un

configurable

 

‐ 

2

 

Configure

 

as

 

Normal

 

or

 

High

 

High

 

3

 

Configure

 

as

 

Normal

 

or

 

High

 

High

 

4

 

Configure

 

as

 

Normal

 

or

 

High

 

High

 

5

 

Configure

 

as

 

Normal

 

or

 

High

 

High

 

6

 

Configure

 

as

 

Normal

 

or

 

High

 

High

 

IR Port Output Power 

 
 

IR

 

Code

 

Learning

 

 

Learning

 

IR

 

Code

 

on

 

ZXT

310

  

(Learn

 

an

 

IR

 

control

 

code

 

from

 

the

 

original

 

remote

 

control

 

to

 

ZXT

310)

 

 

L

 

Important

 

 

Please

 

make

 

sure

 

that

 

the

 

“End

 

point

 

selection

 

control”

 

has

 

completed

 

(if

 

necessary)

 

before

 

process

 

the

 

following

 

setup.

 

 

Step

 

Setup

 

Key

 

LED

 

Indication

 

Status

 

on

         

ZXT

310

 

1

 

Make

 

sure

 

ZXT

310

 

switched

 

to

 

Channel

 

1

 

(EP1)

 

 

LED

 

flashes

 

once

 

then

 

keep

 

on

 

2

 

Refer

 

to

 

your

 

primary

 

controller

 

instructions

 

to

 

process

 

the

 

configuration

 

setup

 

procedure.

  

  ‐ 

Parameter:

 

25

 

(0x19)

 

  ‐ 

Value:

 

0001

  

(0x0001)

 

 

(Z

Wave

 

Cmd#,

 

e.g.

 

if

 

POWER

 

key

 

is

 

going

 

to

 

be

 

learnt,

 

input

 

the

 

value:

 

39

  

(0x27)

   

‐ 

3

 

Place

 

the

 

ZXT

310

 

and

 

your

 

original

 

remote

 

on

 

a

 

flat

 

surface,

 

aimed

 

at

 

each

 

other

 

and

 

1

3

 

cm

 

apart

 

from

 

the

 

“L”

 

learning

 

mark.

 

‐ 

4

 

Press

 

and

 

keep

 

holding

 

the

 

key

 

on

 

your

 

original

 

equipment

 

remote

 

which

 

you

 

want

 

to

 

learn

 

for

 

a

 

few

 

 

LED

 

flashes

 

twice

 

then

 

keep

 

on

 

Summary of Contents for ZXT-310

Page 1: ...1 ZXT 310 Z Wave to AV IR Extender Firmware Version V1 0 V1 1 V1 2 ...

Page 2: ...le AV channel 9 IR Code Selection 10 IR Port Mapping 11 IR Output Power 12 IR Code Learning 13 Reset ZXT 310 to factory default 14 ZXT 310 Information 15 IR Transmission mode 15 End Point Selection Control 16 Z Wave Configuration Parameters 17 Installation 21 Mounting the ZXT 310 to a wall 21 Wireless Information 23 Maintenance 23 Frequently Asked Questions 23 Technical Specifications 25 Checking ...

Page 3: ...n diagram It also supports Z Wave networks with multiple gateways and controllers Like every Z Wave accessory the user will need to include the ZXT 310 into his Z Wave network using the primary controller Then the user can use either the primary controller or secondary controller to configure and setup the ZXT 310 using Z Wave s configuration command class Once the configuration and setup is compl...

Page 4: ...any knowledge related to IR control code It also eliminates the need for complex set up procedures and proprietary Z Wave commands to configure the system The IR code library supports various brand name of AV equipment found in the today s market User can use his controller or gateway to send a 4 digits AV IR code number include the brand selection using standard Z Wave configuration command Host ...

Page 5: ...unique ID code so that controllers not in the network cannot control the system Primary Controller The first controller is used to set up your devices and network Only the Primary Controller can be used to include or delete modules from a network It is recommended that you mark the primary controller for each network for ease in modifying your network Network Wide Inclusion NWI Network Wide Inclus...

Page 6: ...e INSTALLATION if it is needed to mount the ZXT 310 to a wall Power up the ZXT 310 by the supplied AC DC adaptor L CAUTION Be sure to always use the supplied AC DC adaptor Do not try to power up other device with the supplied AC DC adaptor This could damage the AC DC adaptor or the connected device Please carefully read through the following then store the manual for future reference ...

Page 7: ...LED flashes once then keep on 2 Refer to your primary controller instructions to process the inclusion setup procedure 3 Press the PROG button on ZXT 310 LED flashes twice then keep on Device inclusion completed Note 1 Red LED flashes 6 times means the setup process is failed Please redo the process again Note 2 If you can t add the ZXT 310 to network it might have been included in another Z Wave ...

Page 8: ...us on ZXT 310 1 Make sure ZXT 310 switched to Channel 1 EP1 LED flashes once then keep on 2 Refer to your primary controller instructions to process the exclusion setup procedure 3 Press the PROG button on ZXT 310 LED flashes twice then keep on Device exclusion completed ...

Page 9: ...t Simple AV Channel is a Z Wave virtual channel and it is not related to IR Port output User can use the IR Port Mapping function to map the IR port output to Simple AV Channel AV device Figure 3 Z Wave to IR Channel EP and IR Ports Device End point no IR code no IR output port no IR output power Device icon 1 Device icon 2 Device icon 3 Device icon 4 Device icon 5 Device icon 6 Configuration data...

Page 10: ...XT 310 1 Make sure ZXT 310 switched to Channel 1 EP1 LED flashes once then keep on 2 Refer to your primary controller instructions to process the configuration setup procedure Parameter 27 Value 0001 Refer to IR code list of ZXT 310 3 Press the PROG button on ZXT 310 LED flashes twice then keep on Entering device code successful Note 1 Red LED flashes 6 times means that the setup process is failed...

Page 11: ...er instructions to process the configuration setup procedure Parameter 29 Value 01 Enter the IR port number 1 6 which you want to transmit the IR signal 3 Press the PROG button on ZXT 310 LED flashes twice then keep on Set IR Port output successful Note 1 Red LED flashes 6 times means that the setup process is failed Please redo the process again Note 2 All the Simple AV Channel Z Wave to IR Chann...

Page 12: ... primary controller instructions to process the configuration setup procedure Parameter 28 0x1C Value 255 0xFF Set IR output power level by entering 0 0x00 Normal power mode 255 0xFF High power mode default is in high power mode 3 Press the PROG button on ZXT 310 LED flashes twice then keep on Set IR Power level successful Note 1 Red LED flashes 6 times means that the setup process is failed Pleas...

Page 13: ...l has completed if necessary before process the following setup Step Setup Key LED Indication Status on ZXT 310 1 Make sure ZXT 310 switched to Channel 1 EP1 LED flashes once then keep on 2 Refer to your primary controller instructions to process the configuration setup procedure Parameter 25 0x19 Value 0001 0x0001 Z Wave Cmd e g if POWER key is going to be learnt input the value 39 0x27 3 Place t...

Page 14: ...witched to power off Press the key on original remote before learning mode timeout Keep away from incandescent light and direct sunlight during learning Make sure IR Transmitter of your original remote alight with learning diode of ZXT 310 you may also slight adjust closer or further away the distance of two devices Some of remotes the IR transmitter in hidden behind lens and may not installed cen...

Page 15: ...ill report the supported command class IR Transmission Mode Set IR transmission mode for IR transmission Step Setup Key LED Indication Status on ZXT 310 1 Make sure ZXT 310 switched to Channel 1 EP1 LED flashes once then keep on 2 Refer to your primary controller instructions to process the configuration setup procedure Parameter 31 0x1F Value 255 0xFF Set IR output power level by entering 0 0x00 ...

Page 16: ...nnel 1 EP1 LED flashes once then keep on 2 Refer to your primary controller instructions to process the configuration setup procedure Parameter 38 0x26 Value 1 0x01 EP1 2 0x02 EP2 3 0x03 EP3 4 0x04 EP4 5 0x05 EP5 6 0x06 EP6 Enter the Endpoint number 1 6 which you want to configure 3 Press the PROG button on ZXT 310 LED flashes twice then keep on End point selection successful Note 1 Red LED flashe...

Page 17: ... The status value 1 3 4 will be reset to 0 when ZXT 310 receive a get command to this parameter 1 0 0x00 IR channel idle 1 0x01 OK 2 0x02 Downloading 3 0x03 Command Full 4 0x04 Operation Fail Default idle 0x00 23 to 24 0x17 to 0x18 Reserved For internal reference only N A 25 0x19 The Simple AV command number or key going to be learned Any incoming operation may probably to wait up to 15s to releas...

Page 18: ... 1 default 2 0x02 IR Port 2 3 0x03 IR Port 3 4 0x04 IR Port 4 5 0x05 IR Port 5 6 0x06 IR Port 6 30 0x1E Reserved For internal reference only N A 31 0x1F IR transmission mode 1 0 0x00 Continuous IR transmission mode default 255 0xFF Single shot IR transmission mode 32 to 35 0x20 to 0x23 Reserved For internal reference only N A 36 0x24 Check Library Version Read Only 4 Byte 1 2 Firmware Version Byte...

Page 19: ...L Mapping Information BASIC Set Value 0x00 will map to Simple AV key ID Power Off 0x00F7 BASIC set Value 0xFF will map to Simple AV key ID Power 0x0027 AV Command to IR Control Code US BR CN Mapping Table ...

Page 20: ...Command to IR Control Code EU AU IN RU IL Mapping Table L Information If you are using Gateway or other z wave controllers to operate ZXT 310 Please follow the instruction from the gateway or other controller ...

Page 21: ...EDURE PRECAUTIONS Do not modify parts or use the ZXT 310 in ways other than its intended use Doing so could cause the ZXT 310 to fall and result in an injury Be sure to fully check that there are no electrical wires or pipes inside the wall before mounting If any of the screws are loose the ZXT 310 can fall and cause an injury Do not mount the ZXT 310 with the screws still loose Check that the two...

Page 22: ...e screw mounting positions are shown in the figure below Note 1 When mounting the screws to the wall leave a space between the wall and screw cap as shown in the figure 3 Insert the ZXT 310 key holes onto the two screws mounted to the wall and then slide downward to secure in place 4 After securing the ZXT 310 to the wall connect the AC DC adaptor and cables to the ZXT 310 Note 1 Check that the ZX...

Page 23: ...n boxes which could reduce the range by up to 20 to 30 Maintenance 1 Do not expose your unit to dust strong sunlight humidity high temperatures or mechanical shocks 2 Do not use corrosive or abrasive cleansers on your unit 3 Keep the unit dust free by wiping it with a soft dry cloth 4 Do not disassemble your unit it contains no user serviceable parts Frequently Asked Questions Q Why won t my unit ...

Page 24: ...nt to a Scene Group Q How to select my AV equipment IR code from ZXT 310 A You should refer to the code list and look into the Device Brand and try the code no sequentially until you find the right code You can record down your device code under the table for future reference after setting up the ZXT 310 correctly Q ZXT 310 supports external IR emitters but there is no response on the IR emitter s...

Page 25: ...Technical Specifications Model No BW8371US ZXT 310US BW8371EU ZXT 310EU BW8371AU ZXT 310AU BW8371IN ZXT 310IN BW8371RU ZXT 310RU BW8371BR ZXT 310BR BW8371IL ZXT 310IL BW8371CN ZXT 310CN RF Frequency 908 42MHz ZXT 310US 868 42MHz ZXT 310EU 921 42MHz ZXT 310AU 865 22MHz ZXT 310IN 869 02MHz ZXT 310RU 921 42MHz ZXT 310BR 916 02MHz ZXT 310IL 868 42MHz ZXT 310CN RF operating distance up to 80ft outdoor ...

Page 26: ...ction against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to ...

Page 27: ...l government for information regarding the collection systems available There is no user serviceable parts in this unit The socket outlet shall be installed near the equipment and shall be easily accessible Use only power supplies listed in the user instructions Caution Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions Printed in ...

Reviews: