5.7.5 Communication connection
Communication interface
This product has a series communication interfaces besides WIFI or GPRS
(
optional
)
, Dry contact and extend port and for
human and machine communication, etc., can be delivered to PC or other monitoring equipment via these interfaces.
1. WIFI or GPRS
The details please refer to the WIFI or GPRS module user manual.
3. METER port
Meter port PINS definition:
2. ADD Interface
ADD interface PINS definition:
Meter communication: METER_485A & METER_485B----pin1 & pin2
Relay contact output for generator: GENA & GENB----pin3 & pin4
Shut down the hybrid inverter: +5V & SHUTDOWN----pin5 & pin6
Temperature of Lead-acid battery Temp & GND---pin7 and pin8
The function of meter port same as pin1 & pin2 of ADD interface.
Pin
1
METER-485A METER-485B
GENA
GENB
+5V
SHUTOWN
Temp
GND
2
3
4
5
6
7
8
Function
Pin
1
METER-485A METER-485B
NC
NC
NC
NC
NC
NC
2
3
4
5
6
7
8
Function
Meter wiring diagram
4. DRED
This application meets the requirements of local Australian grid code (AS/NZS 4777.2) which, among specific requirements
for connection, calls for compatibility with Demand Response Enabling Devices (DRED). The DRED is under control of a
local network operator and allows to put the inverter in one of the Demand Response Modes (DRMs) defined by the
standard:
·DRM 0 Operate the disconnection device
·DRM 1 Do not consume power
·DRM 2 Do not consume at more than 50% of rated power
·DRM 3 Do not consume at more than 75% of rated power and source reactive power if capable
·DRM 4 Increase power consumption (subject to constraints from other active DRMs)
·DRM 5 Do not generate power
·DRM 6 Do not generate at more than 50% of rated power
·DRM 7 Do not generate at more than 75% of rated power and sink reactive power if capable.
·DRM 8 Increase power generation (subject to constraints from other active DRMs)
Currently, it is mandatory to respond to DRM0, which allows the network manager to remotely decouple the installation
from the distribution network.
DRM PINS definition:
PV Panels
Battery
Normal Load
Grid
AC Switch
Hybrid Inverter
1
2
3
4
5 6
Meter
7
RS485A
RS485B
Pin
1
DRM1/5
DRM2/6
DRM3/7
DRM4/8
+3.3V
COM/DRM0
GND
HND
2
3
4
5
6
7
8
Function