33
MAINTENANCE
Check for cleanliness of the generating set, as it affects efficiency.
Check the oil and air filter often and service regularly as per your manufacturer’s owner’s manual.
Have the AC voltage and hertz checked for proper settings?
Keep the governor and choke linkage clean.
Check the generator starting battery for clean connections and proper state of charge.
Remember the generator runs out of fuel when the tank is below 1/4.
Keep the generator compartment clean do not use as a storage area.
Check the exhaust system often for leaks.
Check manufacturer’s owner’s manual for additional information and to ensure that proper
maintenance has been performed
.
IF SOMETHING GOES WRONG
PROBLEM
Generator will not start
.
Generator has started but is not powering.
Makes a clinking noise when trying to start
.
WHAT TO DO
Check the fuel level. It must be 1/4 full before it will run
and should be filled at this level. If you have continually
tried to start it, it may be flooded. Wait a few minutes
before trying again. Check the oil level; it may not start if
the oil is too low.
Check the fuse on the generator - if blown replace with
same amps as originally installed. Check the main
breaker on the generator and reset if necessary.
Check the battery to see if it has a bad ground or
connection or if the battery is low. Check the position of
the battery disconnect; if not engaged, change
.
Refer to your owner’s manual for more detailed troubleshooting information
.
AGS
setting in multiplex
Summary of Contents for vienna 2021