111
5.2.10
GO_OPTION: GP
Description:
Sets or displays the emulation mode during user program execution.
Format:
gp
Displays emulation mode for user program execution.
gp <eml_opt>
<eml_opt> = eml_mode <eml_mode>
Sets emulation mode for user program execution.
Table 5.11 GO_OPTION Command Parameter
Parameter
Type
Description
<eml_mode>
Keyword
Specifies the emulation mode.
Set either of the following:
normal: Normal execution
no_break: Makes software breakpoints and
hardware breakpoints temporarily invalid and
executes the user program.
Note:
The parameters for this command vary with the product. For the specifications of each
product, refer to the on-line help.
Examples:
To display the currently set emulation mode for user program execution:
>
gp (RET)
The display format is as follows:
>gp
Emulator execution mode = Normal
To set the normal emulation mode for user program execution:
>
gp eml_mode normal (RET)
Note: The items displayed with this command vary with the product. For the display
specifications of each product, refer to the on-line help.
Summary of Contents for H8S/2378F
Page 5: ...H8S 2378F E10A Emulator User s Manual User s Manual Rev 1 0 2002 10...
Page 14: ...VIII...
Page 77: ...53 Enter H 10a4 to the Value edit box Figure 3 35 Breakpoint Dialog Box Click the OK button...
Page 90: ...66...
Page 120: ...96...