ISL9241EVAL1Z
5. Typical Performance Curves
UG184 Rev.3.00
Page 25 of 28
Aug.26.19
Figure 26. OTG mode enable using OTGEN pin.
V
BAT
= 11V, V
OTG
= 5V, general purpose comparator
disabled, OTGEN Control bit enabled
Figure 27. OTG mode transient. V
BAT
= 11V,V
OTG
= 5V,
load = 0.5A to 2A
Figure 28. Bypass (HPBB) mode, reverse turbo boost
enabled. Output voltage loop to adapter current limit
loop transition. V
ADP
= 20V, V
BAT
= 12V,
MaxsystemVoltage = 13.04V, Adapter_current_limit = 3A,
Charge_current = 0A, System_load = 0.5A to 6A
Figure 29. Bypass (HPBB) mode, reverse turbo boost
enabled. Charge current loop to adapter current limit
loop transition. V
ADP
= 20V, V
BAT
= 12V,
MaxsystemVoltage = 13.04V, Adapter_current_limit = 3A,
Charge_current = 3A, System_load = 0.5A to 6A