R01UH0823EJ0100 Rev.1.00
Page 1557 of 1823
Jul 31, 2019
RX23W Group
44. 12-Bit A/D Converter (S12ADE)
44.2.16
A/D Event Link Control Register (ADELCCR)
x: Don't care
ADELCCR sets the generation conditions of the ELC scan end event (S12ADELC).
ELCC[1:0] Bits (Event Link Control)
These bits select the generation conditions of the scan end event (S12ADELC) for the ELC.
Address(es): S12AD.ADELCCR 0008 907Dh
b7
b6
b5
b4
b3
b2
b1
b0
—
—
—
—
—
—
ELCC[1:0]
Value after reset:
0
0
0
0
0
0
0
0
Bit
Symbol
Bit Name
Description
R/W
b1, b0
Event Link Control
b1 b0
0 0: Event is generated on completion of the scan other than group
B in group scan mode
0 1: Event is generated on completion of the scan of group B in
group scan mode
1 x: Event is generated on completion of all scans
R/W
b7 to b2
—
Reserved
These bits are read as 0. The write value should be 0.
R/W