R01UH0823EJ0100 Rev.1.00
Page 413 of 1823
Jul 31, 2019
RX23W Group
20. Event Link Controller (ELC)
Table 20.3
Correspondence between Values Set in ELSRn.ELS[7:0] Bits and Event Signals (1/2)
ELS[7:0] Bit Value
Peripheral Modules
Event Signal Set in ELSRn
08h
Multifunction timer pulse unit 2
MTU1 compare match 1A
09h
MTU1 compare match 1B
0Ah
MTU1 overflow
0Bh
MTU1 underflow
0Ch
MTU2 compare match 2A
0Dh
MTU2 compare match 2B
0Eh
MTU2 overflow
0Fh
MTU2 underflow
10h
MTU3 compare match 3A
11h
MTU3 compare match 3B
12h
MTU3 compare match 3C
13h
MTU3 compare match 3D
14h
MTU3 overflow
15h
MTU4 compare match 4A
16h
MTU4 compare match 4B
17h
MTU4 compare match 4C
18h
MTU4 compare match 4D
19h
MTU4 overflow
1Ah
MTU4 underflow
1Fh
Compare match timer
CMT1 compare match 1
22h
8-bit timers
TMR0 compare match A0
23h
TMR0 compare match B0
24h
TMR0 overflow
28h
TMR2 compare match A2
29h
TMR2 compare match B2
2Ah
TMR2 overflow
2Eh
Realtime clock
RTC periodic event
(select 1/256, 1/128, 1/64, 1/32, 1/16, 1/8, 1/4, 1/2, 1, or 2 seconds)
31h
Independent watchdog timer
IWDT underflow or refresh error
32h
Low power timer
LPT compare match
34h
12-bit A/D converter
S12AD comparison conditions are met
35h
S12AD comparison conditions are not met
3Ah
Serial communications interfaces
SCI5 error (receive error or error signal detection)
3Bh
SCI5 receive data full
3Ch
SCI5 transmit data empty
3Dh
SCI5 transmit end
4Eh
I
2
C bus interface
RIIC0 communication error or event generation
4Fh
RIIC0 receive data full
50h
RIIC0 transmit data empty
51h
RIIC0 transmit end
52h
Serial peripheral interface
RSPI0 error (mode fault, overrun, or parity error)
53h
RSPI0 idle
54h
RSPI0 receive data full
55h
RSPI0 transmit data empty
56h
RSPI0 transmit end