R01UH0823EJ0100 Rev.1.00
Page 574 of 1823
Jul 31, 2019
RX23W Group
23. Multi-Function Timer Pulse Unit 2 (MTU2a)
Figure 23.66
Example of Output Phase Switching through UF, VF, and WF Bit Settings (2)
(q) A/D Converter Start Request Setting
In complementary PWM mode, an A/D converter start request can be issued using the MTU3.TGRA compare match, the
MTU4.TCNT underflow (trough), or compare match on a channel other than MTU3 and MTU4.
When start requests using the MTU3.TGRA compare match are specified, A/D conversion can be started at the crest of
the MTU3.TCNT count.
A/D converter start requests can be specified by setting the TIER.TTGE bit to 1. To issue an A/D converter start request
at an MTU4.TCNT underflow (trough), set the MTU4.TIER.TTGE2 bit to 1.
UF bit
VF bit
WF bit
MTIOC3B pin
MTIOC3D pin
MTIOC4A pin
MTIOC4C pin
MTIOC4B pin
MTIOC4D pin
TGCR
6-phase output
When TGCR.BDC = 1, TGCR.N = 1, TGCR.P = 1, and TGCR.FB = 1,
the high level is the active level for output.