R01UH0823EJ0100 Rev.1.00
Page 810 of 1823
Jul 31, 2019
RX23W Group
29. Low-Power Timer (LPT)
29.2.2
Low-Power Timer Control Register 2 (LPTCR2)
Note:
Set the PRCR.PRC2 bit to 1 (write enabled) before rewriting this register.
The LPTCR2 register is used to control supply of the clock to be used for the low-power timer.
LPCNTSTP Bit (Clock Supply Control)
This bit is used to supply or stop the clock to be used for the low-power timer. When this bit is set to 0, the clock signal is
supplied to the low-power timer counter and divider.
Address(es): LPT.LPTCR2 0008 00B1h
b7
b6
b5
b4
b3
b2
b1
b0
—
—
—
—
—
—
—
LPCNT
STP
Value after reset:
0
0
0
0
0
0
0
1
Bit
Symbol
Bit Name
Description
R/W
b0
Clock Supply Control
0: Clock is supplied to the low-power timer
1: Supply of clock to the low-power timer is stopped
R/W
b7 to b1
—
Reserved
These bits are read as 0. The write value should be 0.
R/W