3
1.2
Connecting the Emulator with the User System
To connect the E10A emulator (hereinafter referred to as the emulator), the H-UDI port connector
must be installed on the user system to connect the user system interface cable. When designing
the user system, refer to an example of recommended connection between the connector and the
MPU shown in this manual. In addition, read the E10A emulator user's manual and hardware
manual for the related device.
Table 1.2 shows the type number of the emulator, the corresponding connector type, and the use of
AUD function.
Table 1.2 Type Number, AUD Function, and Connector Type
Type Number
Connector
AUD Function
HS7710KCM02H, HS7710KCI02H
36-pin connector
Available
HS7710KCM01H, HS7710KCI01H
14-pin connector
Not available
The H-UDI port connector has the 36-pin and 14-pin types as described below. Use them
according to the purpose of the usage.
1. 36-pin type (with AUD function)
The AUD trace function is supported. A large amount of trace information can be acquired in
realtime. The window trace function is also supported for acquiring memory access in the
specified range (memory access address or memory access data) by tracing.
2. 14-pin type (without AUD function)
The AUD trace function cannot be used because only the H-UDI function is supported. For
tracing, only the internal trace function is supported. Since the 14-pin type connector is
smaller than the 36-pin type (1/2.5), the area where the connector is installed on the user
system can be reduced.