EN
FAQ - English
For chapter indications, refer to the complete instruction manual on the internet.
Problem
Possible cause
Corrective action
Insufficient extraction
power.
• Extraction duct blocked.
• Extraction grate blocked.
• Remove and clean the extraction duct.
• Remove and clean the extraction grate.
Lamp does not
switch on.
• Power cord not plugged in.
• Illumination defect.
• Faulty electronics.
The device with fluorescent tubes
•
The fluorescent tube is not situated correctly
in the socket.
• Fluorescent tubes defect.
• Plug the power cord in.
• Change light using the service or see spare
part list.
• Have Customer Service replace the electron-
ics or refer to the Spare Parts List.
•
Check that the fluorescent tube is fitted
correctly (see chapter 5.4.2).
•
Changing the fluorescent tubes (see chap
-
ter 5.4.2).