1.  Introduction

1.1  Description

This safety burner eco, is a stable and reliable laboratory burner.

As soon as the flame goes out, within 90 seconds a safety valve activates to create an automatic gas 

lock. This stops further gas from flowing. The gas consumption of this burner is low because you are 

able to control the gas flow with a gas valve according to your requirements. 

1.2  Symbols used

In these instructions for use and on the burner itself, you will find these symbols with the following 

meanings:

  Danger 

Immediate danger. Observe the accompanying documentation!

  Warning 

By not following the instructions the burner could become damaged.

 Note 

Useful tips for operation or use.

 Mark of conformity DVGW (Deutscher Verein des Gas- und Wasserfaches e.V.). 

 

► List, particular attention should be paid:

• 

List

 -List according to importance

 

Handling instructions / required action / input / operation sequence: 

You will be asked to carry out the given task in the specified order. 

 

Result of the task / reaction of the unit / reaction of the programme: 

The unit or the programme does not react to your action, or due to another incident.

Other symbols are described during use.

Summary of Contents for Safety Burner eco 934 0100

Page 1: ...E Bedienungsanleitung Bedienungsanleitung Instruction manual Mode d emploi Istruzioni d uso Instrucciones para el servicio Instru es de uso Kullan m K lavuzu Datei 216715_01 Titel nderungsstand 20 08...

Page 2: ...you will find these symbols with the following meanings Danger Immediate danger Observe the accompanying documentation Warning By not following the instructions the burner could become damaged Note Us...

Page 3: ...g smell of gas be detected close the gas shut off valve at the laboratory work bench immediately and initiate the corresponding safety measures see DVGW law and valid national regulations Always pay a...

Page 4: ...at the laboratory workbench gas isolation valve Slide the certified gas hose in Germany according to DIN 30664 or DVGW G 5501 P up to the last groove of the hose spout 5 on the burner If necessary sec...

Page 5: ...the burner once it is completely cool Before cleaning close the gas shut off valve at the laboratory workbench gas isolation valve Do not use chemicals for cleaning Never drill or unscrew the burner n...

Page 6: ...l not ignite despite open shut pff valve at the laboratory workbench gas isolation valve no audible gas flow The main gas supply has not been switched on gas bottle is empty The actuation knob for aut...

Page 7: ...may only be changed by qualified personnel according to the DVGW or valid natio nal regulations 10 Guarantee All burners are checked before distribution If you discover any functioning fault please se...